Transcription

HPE MSA 1060/2060/2062 Installation GuideAbstractThis document describes initial hardware setup for HPE MSA 1060/2060/2062 controller enclosures and disk enclosures,and is intended for use by storage system administrators familiar with servers and computer networks, networkadministration, storage system installation and configuration, storage area network management, and relevant protocols.Part Number: R0Q73-90006Published: September 2020Edition: 1

Copyright 2020 Hewlett Packard Enterprise Development LPThe information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warrantystatements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable fortechnical or editorial errors or omissions contained herein.Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use, or copying. Consistent with FAR 12.211 and 12.212, Commercial ComputerSoftware, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard Enterprise has no control over and is not responsible for information outsidethe Hewlett Packard Enterprise website.AcknowledgmentsIntel , Itanium , Pentium , Intel Inside , and the Intel Inside logo are trademarks of Intel Corporation in the United States and other countries.Microsoft and Windows are U.S. trademarks of the Microsoft group of companies.Adobe and Acrobat are trademarks of Adobe Systems Incorporated.Java and Oracle are registered trademarks of Oracle and/or its affiliates.UNIX is a registered trademark of The Open Group.Revision HistoryR0Q73-90006Initial HPE release.May 2020

Contents1 Overview8MSA 1060/2060/2062 Storage modelsMSA 1060/2060/2062 enclosure user interfacesMSA 1060/2060/2062 controllersFeatures and benefitsProduct QuickSpecsRelated MSA documentation8889992 Components103 Installing the enclosures204 Connecting hosts275 Connecting to the controller CLI port40Front panel componentsAttach the enclosure bezel24-drive controller enclosure or expansion enclosure12-drive controller enclosure or expansion enclosureDisks used in storage enclosuresController enclosure—rear panel layoutMSA 2060/2062 controller module—rear panel componentsMSA 1060 controller module—rear panel componentsDisk enclosuresCacheNon-volatile memorySupercapacitor pack101011121314151617181819Installation checklistFDE considerationsConnecting controller and disk enclosuresVerify enclosure connectionsPowering on/powering off2020212323Host system requirementsHost interface protocolsFibre Channel protocoliSCSI protocolSAS protocolAbout data host connectionMSA 2060 and MSA 2062 Storage16Gb Fibre Channel host connect10GbE iSCSI host connect12Gb mini-SAS HD host connectMSA 1060 Storage16Gb Fibre Channel host connect10GBase-T iSCSI host connect12Gb mini-SAS HD host connectConnecting the enclosure to data hostsConnecting direct attach configurationsConnecting switch attach configurationsConnecting management hosts over an Ethernet networkConnecting two storage systems to replicate volumesCabling for replicationHost ports and replicationUpdating 39Device descriptionEmulated serial portPreparing a Linux system for cabling to the CLI portPreparing a Windows system for cabling to the CLI port40404041Contents3

Obtaining IP valuesSetting network port IP addresses using DHCPSetting network port IP addresses using the CLI port and cableUsing the CLI port and cable — known issues on WindowsProblemWorkaround6 Basic operation467 Troubleshooting478 Support and other resources64A LED descriptions67Accessing the SMUConfiguring and provisioning the storage systemUSB CLI port connectionFault isolation methodologyBasic stepsOptions available for performing basic stepsPerforming basic stepsIf an expansion enclosure does not initializeCorrecting enclosure IDsStopping I/ODiagnostic stepsController failureIsolating a host side connection faultHost-side connection troubleshooting featuring FC and iSCSI host portsHost-side connection troubleshooting featuring SAS host portsIsolating a controller module expansion port connection faultIsolating Remote Snap replication faultsReplication setup and verificationDiagnostic steps for replication setupCan you successfully use the Remote Snap feature?Can you create a replication set?Can you replicate a volume?Has a replication run successfully?Resolving voltage and temperature warningsSensor locationsPower supply sensorsCooling fan sensorsTemperature sensorsPower and Cooling Module voltage sensorsAccessing Hewlett Packard Enterprise SupportAccessing updatesRemote supportWarranty informationRegulatory informationDocumentation feedbackFront panel LEDsEnclosure bezel24-drive controller enclosure or supported expansion enclosure12-drive controller enclosure or supported expansion enclosureEar covers and hubcapsDisk drive LEDsRear panel LEDsController enclosure—rear panel layoutMSA 2060/2062 FC controller module—rear panel LEDsMSA 2060/2062 iSCSI controller module—rear panel LEDsMSA 2060/2062 SAS controller module—rear panel LEDsMSA 1060 FC controller module—rear panel 9707071727273747576

MSA 1060 iSCSI controller module—rear panel LEDsMSA 1060 SAS controller module—rear panel LEDsCache Status LED detailsMSA 1060/2060/2062 PCMs—rear panel layoutMSA 1060/2060/2062 drive enclosure—rear panel layout7778797980B Specifications and requirements83C Electrostatic discharge87D SAS fanout cable option88Index89Safety requirementsSite requirements and guidelinesSite wiring and AC power requirementsSite wiring and DC power requirementsWeight guidelinesElectrical guidelinesVentilation requirementsCabling requirementsManagement host requirementsPhysical requirementsEnvironmental requirementsElectrical requirementsSite wiring and power requirements83838383848484848585858686Preventing electrostatic dischargeGrounding methods to prevent electrostatic discharge8787Locate the SAS fanout cable88Contents5

FiguresFigure 1 Bezel used with MSA 1060/2060/2062 Storage enclosures: front panelFigure 2 Attaching/removing the enclosure front bezelFigure 3 24-drive enclosure shown with hubcaps only (no bezel)Figure 4 24-drive controller or expansion enclosure: front panel with hubcaps removedFigure 5 12-drive enclosure shown with hubcaps only (no bezel)Figure 6 12-drive controller or expansion enclosure: front panelFigure 7 Controller enclosure: rear panelFigure 8 MSA 2060/2062 controller module face plate (16Gb FC)Figure 9 MSA 2060/2062 controller module face plate (10GbE iSCSI)Figure 10 MSA 2060 controller module face plate (12Gb mini-SAS HD)Figure 11 MSA 1060 controller module face plate (16Gb FC)Figure 12 MSA 1060 controller module face plate (10GBase-T iSCSI)Figure 13 MSA 1060 controller module face plate (12Gb mini-SAS HD)Figure 14 Disk enclosure supporting either LFF or SFF disksFigure 15 Cabling connections between controller and single drive enclosureFigure 16 Cabling connections between controller and drive enclosuresFigure 17 AC Power and Cooling ModuleFigure 18 DC Power and Cooling ModuleFigure 19 DC power cable section featuring lug connectorsFigure 20 Reference showing qualified SFP option and FC or iSCSI controller moduleFigure 21 Host connect: direct attach—one server/one HBA/dual pathFigure 22 Host connect: direct attach—one server/one HBA/dual pathFigure 23 Host connect: direct attach—two servers/one HBA per server/dual pathFigure 24 Host connect: direct attach—two servers/one HBA per server/dual pathFigure 25 Host connect: direct attach—four servers/one HBA per server/dual pathFigure 26 Host connect: direct attach—four servers/one HBA per server/dual path (fanout)Figure 27 Host connect: switch attach—two servers/two switchesFigure 28 Host connect: switch attach—two servers/two switchesFigure 29 Host connect: switch attach—four servers/multiple switches/SAN fabricFigure 30 Connecting two storage systems for Remote Snap: multiple servers/one switch/one locationFigure 31 Connecting two storage systems for Remote Snap: multiple servers/one switch/one locationFigure 32 Connecting two storage systems for Remote Snap: multiple servers/switches/one locationFigure 33 Connecting two storage systems for Remote Snap: multiple servers/switches/one locationFigure 34 Connecting two storage systems for Remote Snap: multiple servers/switches/two locationsFigure 35 Connecting two storage systems for Remote Snap: multiple servers/switches/two locationsFigure 36 Connecting a USB cable to the CLI portFigure 37 Bezel used with MSA 1060/2060/2062 enclosures: front panelFigure 38 Partial exploded view showing alignment of bezel componentsFigure 39 Details showing backside of bezel fitted to hubcapsFigure 40 LEDs: 24-drive controller or expansion enclosure—front panelFigure 41 LEDs: 12-drive controller or expansion enclosure—front panelFigure 42 Cover details for enclosure earsFigure 43 LEDs: Disk drive combinations — enclosure front panelFigure 44 MSA 1060/2060/2062: rear panelFigure 45 LEDs: MSA 2060/2062 FC controller moduleFigure 46 LEDs: MSA 2060/2062 iSCSI controller moduleFigure 47 LEDs: MSA 2060/2062 SAS controller moduleFigure 48 LEDs: MSA 1060 FC controller moduleFigure 49 LEDs: MSA 1060 iSCSI controller moduleFigure 50 LEDs: MSA 1060 SAS controller moduleFigure 51 LEDs: MSA 1060/2060/2062 Power and Cooling Module (AC/DC)Figure 52 Expansion enclosure rear panel: 12-drive and 24-drive modelsFigure 53 LEDs: MSA 1060/2060/2062 drive enclosure rear 72737475767778808181

TablesTable 1 Related MSA documentationTable 2 Installation checklistTable 3 Supported terminal emulator applicationsTable 4 Terminal emulator display settingsTable 5 Terminal emulator display settingsTable 6 Terminal emulator connection settingsTable 7 Diagnostics LED status: Front panel "Fault/Service Required"Table 8 Diagnostics LED status: Rear panel "FRU OK"Table 9 Diagnostics LED status: Rear panel "Fault/Service Required"Table 10 Diagnostics LED status: Front panel disks "Online/Activity" and "Fault/UID"Table 11 Diagnostics LED status: Front panel disks "Fault/UID"Table 12 Diagnostics LED status: Front panel disks "Fault/UID"Table 13 Diagnostics LED status: Rear panel "Host Link Status"Table 14 Diagnostics LED status: Rear panel "Expansion Port Status"Table 15 Diagnostics LED status: Rear panel "Network Port Link Status"Table 16 Diagnostics LED status: Rear panel power supply module "PCM OK"Table 17 Diagnostics LED status: Rear panel power supply module "AC Fail/Fan Fail/DC Fail"Table 18 Diagnostic LED status: Rear panel "Cache Status"Table 19 Diagnostics for replication setup: Using Remote Snap featureTable 20 Diagnostics for replication setup: Creating a replication setTable 21 Diagnostics for replication setup: Replicating a volumeTable 22 Diagnostics for replication setup: Checking for a successful replicationTable 23 Power supply sensor descriptionsTable 24 Controller platform temperature sensor descriptionsTable 25 PCM temperature sensor descriptionsTable 26 PCM voltage sensor descriptionsTable 27 Cache Status LED — power on behaviorTable 28 PCM LED statesTable 29 LEDs: MSA 1060/2060/2062 expansion activity statesTable 30 Rackmount enclosure dimensionsTable 31 Rackmount enclosure 626263637980818585Contents7

1OverviewHPE MSA storage models are storage solutions combining outstanding performance with high reliability, availability,flexibility, and manageability. MSA 1060 enclosure models blend economy with utility for scalable storage applications.MSA 2060/2062 enclosure models provide enhanced performance and features.MSA 1060/2060/2062 Storage modelsThe MSA enclosures are Storage Bridge Bay (SBB) compliant. The 2U12 enclosure supports 12 large form factor (LFF)disks in a chassis, and the 2U24 enclosure supports 24 small form factor (SFF) disks in a chassis using either AC powersupplies or DC power supplies (2060/2062 only).NOTE For additional information about these controller enclosures, see the following subsections:l"Controller enclosure—rear panel layout" on page 14l"Rear panel LEDs" on page 72The MSA 1060/2060/2062 enclosures support virtual storage. For virtual storage, a group of disks with an assigned RAIDlevel is called a disk group.MSA 1060/2060/2062 enclosure user interfacesMSA enclosures are managed by the Storage Management Utility (SMU), which is a web-based application forconfiguring, monitoring, and managing the storage system. Both the SMU and the command-line interface (CLI) arebriefly described.llThe SMU is the web interface that manages the storage system.The CLI manages the storage system using command syntax entered via the keyboard or scripting, and is the onlymethod available for accessing many advanced features.NOTE For more information about the SMU, see the HPE MSA 1060/2060/2062 Storage Management Guide or onlinehelp. For more information about the CLI, see the HPE MSA 1060/2060/2062 CLI Reference Guide. See also "RelatedMSA documentation" on the facing page.MSA 1060/2060/2062 controllersThe MSA 1060/2060/2062 controller enclosures are pre-configured at the factory to support one of these host interfaceprotocols:l16Gb SFP FCl10GBase-T iSCSI (MSA 1060 only)l10Gb SFP iSCSI (MSA 2060/2062 only)l12Gb mini-SAS HDFor FC and iSCSI host interfaces, a small form-factor pluggable (SFP) transceiver supporting the pre-configured hostinterface protocol is used. For MSA 2060/2062 controllers, you must locate the SFPs and install them into the hostinterface ports. For MSA 1060 FC controllers, the SFPs are pre-installed. MSA controller enclosures do not allow you tochange the host interface protocol. Always use qualified SFP transceivers and cables for supporting the host interfaceprotocol as described in your product's QuickSpecs. For more information, see "Product QuickSpecs" on the facing page.NOTE See HPE MSA Transceiver Replacement Instructions at www.hpe.com/info/msadocs when installing qualifiedSFPs into FC and iSCSI controller modules.8Chapter 1 Overview

For the mini-SAS HD host interface, both standard and fanout cables (MSA 1060 SAS only) are supported for hostconnection. Always use qualified SAS cable options for supporting the host interface protocol as described in yourproduct's QuickSpecs (see "Product QuickSpecs" below for more information). Host connection for mini-SAS HD controllermodules are described by cabling diagrams in "Connecting hosts" on page 27. Connection information for the SASfanout cable option is provided in "SAS fanout cable option" on page 88.TIP See the topic about configuring host ports within the Storage Management Guide.MSA SAS controllers provide two (MSA 1060) or four (MSA 2060/2062) high density mini-SAS (mini-SAS HD) ports percontroller module. The mini-SAS HD host interface protocol uses the SFF-8644 external connector interface defined forSAS 3.0 to support a link rate of 12 Gb/s using the qualified connectors and cable options.Features and benefitsProduct features and supported options are subject to change. Online documentation describes the latest product andproduct family characteristics, including currently supported features, options, technical specifications, configurationdata, related optional software, and product warranty information. For more information, see "Related MSAdocumentation" below and "Support and other resources" on page 64.Product QuickSpecsCheck the QuickSpecs for a complete list of supported servers, operating systems, and options. /MSA2062QuickSpecsRelated MSA documentationRelated support information is provided in "Support and other resources" on page 64. Product documentation titlespertaining to management interfaces are shown in the table below.Table 1 Related MSA documentationFor information aboutSeeUsing the Storage Management Utility (SMU) web interface toconfigure and manage the productHPE MSA 1060/2060/2062 Storage Management GuideUsing the command-line interface (CLI) to configure and manage HPE MSA 1060/2060/2062 CLI Reference Guidethe productEvents codes and recommended actionsHPE MSA Event Descriptions Reference GuideTo access the above MSA documentation, see the Hewlett Packard Enterprise Information Library:www.hpe.com/info/msadocs.NOTE The table above provides titles of related MSA documents used with this guide. These documents areinformally referenced within this guide as follows:lStorage Management GuidelCLI Reference GuidelEvent Descriptions Reference GuideChapter 1 Overview9

2ComponentsFront panel componentsHPE MSA 1060/2060/2062 Storage enclosures support 2U12 and 2U24 enclosure configurations as specified in the Notebelow. The 2U12 supports 12 LFF 3.5" disks and the 2U24 supports 24 SFF 2.5" disks. The disk modules are accessed fromthe enclosure front panel. See also the topics about disk modules:l"24-drive controller enclosure or expansion enclosure" on the facing pagel"12-drive controller enclosure or expansion enclosure" on page 12l"Disks used in storage enclosures" on page 13NOTE Supported storage enclosure configurations:lMSA 2060/2062 supports 2U24 and 2U12 chassis as controller enclosures and disk enclosures.lMSA 2062 uses two SSD drives pre-installed in drive slots 1 and 2.llMSA 1060 supports the 2U24 chassis as a controller enclosure or disk enclosure, while supporting the 2U12 chassis asa disk enclosure only.MSA 1060/2060/2062 controller enclosures support only same generation MSA 12Gb disk enclosures that aredescribed in this guide. Earlier MSA 6Gb LFF and SFF disk enclosures are incompatible.The enclosure front panel provides a passive, non-replaceable status panel mounted on the left ear flange. This panelprovides enclosure status LEDs, and it is protected by a cover.Figure 1 Bezel used with MSA 1060/2060/2062 Storage enclosures: front panelA flexible cable connects the panel to the midplane. The panel provides the functions described in the 24-drive and 12drive front panel illustrations and their tables. See also the topic about front panel LEDs in "LED descriptions" onpage 67. Hubcaps protect enclosure ears. When the optional enclosure bezel is attached to the hubcaps as shown, thedisks are hidden from view.Attach the enclosure bezelA generic version of the MSA enclosure bezel assembly is shown above. The geometry applies to all product models.Labels and icons may vary slightly between product models. Ear circuitry is protected by a plastic ear cover attached tothe ear flange. Plastic hubcaps snap onto the left and right ear covers. The hubcap for the left ear provides iconsidentifying enclosure status LEDs. The hubcap for the right ear includes a logo and product model on the front face.The right hubcap used on 12-drive enclosures also includes a disk slot index diagram on its left face. The bezelcomponent snaps into the left and right hubcaps.You can attach or remove the optional enclosure bezel. Note that the left end of the bezel includes a release latch.1. Verify that the left and right hubcaps are properly fitted over their ear covers.2. Hook the right end of the bezel into the right hubcap.3. Insert the left end of the bezel into the securing slot until the release latch snaps into place.10Chapter 2 Components

To observe disk LEDs during enclosure operation, you must remove the enclosure bezel. Optionally, you can monitordisk activity using management interfaces when the bezel is attached.NOTE A partial assembly view shows bezel insertion into the right ear hubcap slot. Simplified conceptual graphicsillustrate the enclosure bezel attachment procedure.Figure 2 Attaching/removing the enclosure front bezelTIP To remove the bezel from the enclosure, reverse the order of the steps previously provided.See also, "Enclosure bezel assembly" on page 67 for a partial exploded view showing alignment of enclosure bezelcomponents.The front panel illustrations that follow show the enclosures with the bezel removed, revealing disk modules.24-drive controller enclosure or expansion enclosureFigure 3 24-drive enclosure shown with hubcaps only (no bezel)Chapter 2 Components11

The figure above shows the enclosure with the bezel removed and the disks visible. The following figure shows theenclosure with both the bezel and the hubcaps removed. The enlarged inset in that figure is a detail view showing theicons pertaining to enclosure status LEDs located on the left ear.Left earRight ear123456789 10 11 1213 14 15 16 17 18 19 20 21 22 23 24Ear cover icons for LEDs234156Notes:Integers on disks indicate drive slot numbering sequence.The enlarged detail view at left shows LED icons from the left ear cover that correspond to the chassis LEDs.123Enclosure ID LEDSystem Power LEDModule Fault LED456Unit Identification (UID) LEDDisk drive Fault/UID LEDDisk drive Online/Activity LEDFigure 4 24-drive controller or expansion enclosure: front panel with hubcaps removed12-drive controller enclosure or expansion enclosureRight earFigure 5 12-drive enclosure shown with hubcaps only (no bezel)The figure above shows the enclosure with the bezel removed and the disks visible. The following figure shows theenclosure with both the bezel and the hubcaps removed. The enlarged inset in that figure is a detail view showing theicons pertaining to enclosure status LEDs located on the left ear.12Chapter 2 Components

Right earLeft ear123456789101112Ear cover icons for LEDs234156Notes:Integers on disks indicate drive slot numbering sequence.The enlarged detail view at left shows LED icons from the left ear that correspond to the chassis LEDs.1Enclosure ID LED4Unit Identification (UID) LED23System Power LEDModule Fault LED56Disk drive Fault/UID LEDDisk drive Online/Activity LEDFigure 6 12-drive controller or expansion enclosure: front panelNOTE The hubcaps/ear covers must be attached to the left and right ear flanges on the enclosure front panel toprotect the front status panel and circuitry. Optionally, the bezel can also be attached between the two hubcaps.Disks used in storage enclosuresSupported disk types are described below. For information about creating disk groups and adding spares using thesedifferent disk types, see the Storage Management Guide.MSA 2060 enclosuresEnclosures support LFF Midline SAS, SFF Enterprise SAS, and LFF/SFF SSD disks. They also support LFF Midline SASand SFF Enterprise and LFF/SFF SSD self-encrypting disks that work with the full disk encryption (FDE) feature.MSA 2062 enclosuresThese enclosures support the same disk types supported by MSA 2060 enclosures. A notable configuration exception isthat for these enclosures, two SSDs are pre-installed. One SSD is installed in drive slot 1 and the other SSD is installed indrive slot 2.MSA 1060 enclosuresController enclosures support SFF Enterprise SAS disks and SFF SSDs. Disk enclosures support LFF/SFF Midline SAS disk,LFF/SFF Enterprise SAS disks, and LFF/SFF SSDs.NOTE Disk modules used in MSA 1060/2060/2062 enclosures:lIn addition to the front views of SFF and LFF disk modules shown above, see "Disk drive LEDs" on page 71 forpictorial views.lStorage enclosures may or may not ship with disks pre-installed, depending on order configuration terms.lFor information about installing or replacing disks, see HPE MSA 1060/2060/2062 Drive Replacement Instructions.Chapter 2 Components13

Controller enclosure—rear panel layoutThe diagram and table below display and identify important component items comprising the rear panel layout of arepresentative controller enclosure (4-port Fibre Channel host interface protocol is shown in the example). For a givenhost interface protocol, the rear panel view of an LFF controller enclosure and SFF controller enclosure are identical.MSA 2060/2062 controller enclosure(rear panel locator illustration)1CLICLIMfg 1Mfg 2Mfg 312Gb/s12Gb/sDP 4DP 1CLIMfg 3Mfg 2CLIMfg 14DP 1DP 432ACT2CACHE1CACHEACT561AC Power switch2AC Power and Cooling Module (PCM)3Controller module A (see face plate details)Note: DC PCM is not available with MSA 1060456Controller module B (inverted)DC Power and Cooling Module (2–DC only)DC Power switchFigure 7 Controller enclosure: rear panelA controller enclosure accommodates two Power and Cooling Module (PCM) Field Replaceable Units (FRUs) of the sametype—either both AC or both DC—within the PCM slots (see two instances of callout 2 above). The controller enclosureaccommodates two controller module FRUs of the same type within the controller module slots (see callouts 3 and 4above).TIP The PCMs and controller modules are rotated 180º from their counterparts to align with their respectivemidplane connectors, as shown in the figure above.IMPORTANT HPE MSA enclosures support dual-controller configurations only. If a partner controller fails, thearray will fail over and run on a single controller until the redundancy is restored. A controller module must be installedin each controller module slot to ensure sufficient airflow through the enclosure during operation.IMPORTANT Operation of the enclosure with any plug-in modules missing will disrupt the airflow, and the diskswill not receive sufficient cooling. It is essential that all slots are fitted with appropriate plug-in modules beforepowering on the enclosure.The diagrams with tables that immediately follow provide descriptions of the different controller modules and PCMsthat can be installed into the rear panel of a controller enclosure. Showing controller modules and PCMs separately from14Chapter 2 Components

the enclosure provides improved clarity in identifying the component items called out in the diagrams and described inthe tables. Descriptions are also provided for optional disk enclosures for expanding storage capacity.NOTE Storage enclosures support hot-swap replacement of controller modules, PCMs, disk modules, and I/O modules.Hot-add of disk enclosures is also supported.MSA 2060/2062 controller module—rear panel componentsThe figure below shows four host interface ports configured with 16Gb FC SFP transceivers. See HPE MSA TransceiverReplacement Instructions at www.hpe.com/info/msadocs when installing qualified SFPs into FC controller modules.876 5 4 3 21 FC LEDs1234Host ports: host connection or replicationManufacturing port 3 (service only)Manufacturing port 2 (service only)Manufacturing port 1 (service only)5678CLI port (serial: service only)CLI port (USB–Type B)Network management port (RJ45)SAS expansion port (SFF-8644)Figure 8 MSA 2060/2062 controller module face plate (16Gb FC)The figure below shows four host interface ports configured with 10GbE iSCSI SFP transceivers. See HPE MSATransceiver Replacement Instructions at www.hpe.com/info/msadocs when installing qualified SFPs into iSCSI controllermodules.876 5 4 3 21 10GbE iSCSI LEDsz1234Host ports: host connection or replicationManufacturing port 3 (service only)Manufacturing port 2 (service only)Manufacturing port 1 (service only)5678CLI port (serial: service only)CLI port (USB–Type B)Network management port (RJ45)SAS expansion port (SFF-8644)Figure 9 MSA 2060/2062 controller module face plate (10GbE iSCSI)Chapter 2 Components15

The figure below shows four host interface ports configured with 12Gb/s mini-SAS HD (SFF-8644) connectors.876 5 4 3 21 SAS LEDs1234Host ports: host connectionManufacturing port 3 (service only)Manufacturing port 2 (service only)Manufacturing port 1 (service only)5678CLI port (USB–Type B)CLI port (serial: service only)Network management port (RJ45)SAS expansion port (SFF-8644)Figure 10 MSA 2060 controller module face plate (12Gb mini-SAS HD)MSA 1060 controller module—rear panel componentsThe figure below shows two host interface ports configured with pre-installed 16Gb FC SFP transceivers. If you need toreplace an SFP transceiver, see HPE MSA Transceiver Replacement Instructions at www.hpe.com/info/msadocs.876 5 4 3 21 FC LEDsz1234Host ports: host connection or replicationManufacturing port 3 (service only)Manufacturing port 2 (service only)Manufacturing port 1 (service only)5678CLI port (serial: service only)CLI port (USB–Type B)Network management port (RJ45)SAS expansion port (SFF-8644)Figure 11 MSA 1060 controller module face plate (16Gb FC)16Chapter 2 Components

The figure below shows two host interface ports configured with 10GBase-T iSCSI connectors.876 5 4 3 21 10GBase-T iSCSI LEDs1234Host ports: host connection or replicationManufacturing port 3 (service only)Manufacturing port 2 (service only)Manufacturing port 1 (service only)5678CLI port (serial: service only)CLI port (USB–Type B)Network management port (RJ45)SAS expansion port (SFF-8644)Figure 12 MSA 1060 controller module face plate (10GBase-T iSCSI)This figure below shows two host interface ports configured with 12Gb/s mini-SAS HD (SFF-8644) connectors.876 5 4 3 21 SAS LEDs1234Host ports: host connectionManufacturing port 3 (service only)Manufacturing port 2 (service only)Manufacturing port 1 (service only)5678CLI port (serial: service only)CLI port (USB–Type B)Network management port (RJ45)SAS expansion port (SFF-8644)Figure 13 MSA 1060 controller module face plate (12Gb mini-SAS HD)Disk enclosuresDisk enclosure expansion modules attach to controller modules via the mini-SAS HD expansion port, allowing additionof disks to the storage system. Controller enclosures support attachment of 12Gb disk enclosures using 2U12 and 2U24form factors. The 2U12 chassis supports 1

HPE MSA 1060/2060/2062 Installation Guide Part Number: R0Q73-90006 Published: September 2020 Edition: 1 Abstract This document describes initial hardware setup for HPE MSA