INTERTEK TEST REPORTTom McGlynnWinola Industrial5790 Mislevy RoadFactoryville, PA 18419USAIntertek Test Report Number:Intertek Signed Quote Number (s):Client Reference Number:Product Type:Product Models:Type of Testing Entity:Type of Testing:Test Standard:Evaluation/Testing Location:Date(s) of Testing:103218967CRT-001Qu-00813599308612Ladder PoleHCL-PGE-2BThird Party Testing LaboratoryQualificationANSI/ASSE Z359.1-2007Intertek, 3933 US Rte 11, Cortland NY 13045 **9/6/17Dear Mr. McGlynn,Intertek has completed the evaluation of your ladder model HCL-PGE-2B to the client specified sections of, AmericanNational Standard, Safety Requirements For Personal Fall Arrest Systems, Subsystems and Components,ANSI/ASSE Z359.1-2007. The results of these tests are as indicated below.Tests CompletedTest DateStatic Strength (Ladder Pole)Static Strength (Welded Clip)9/6/179/6/17ANSI/ASSE Z359.1-2007Clause4.3.64.3.6Pass/FailPASSPASSPlease see attached test data for details.This test report concludes the work anticipated in the testing phase of your project.If there are any questions regarding this report please contact the undersigned at 607-753-6711.Tested by,Reviewed by,Matthew StevensTechnicianPerformance GroupAndrew RulisonTeam LeaderPerformance Group** “Intertek Laboratory is ISO/IEC 17025:2005 (CAN-P-4E) accredited by Standards Council of Canada (SCC) with the scope availablefor review at the following location: http://www.scc.ca/en/palcan/38This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibilityand liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance withthe agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution ofthis report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product orservice must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report byitself does not imply that the material, product, or service is or has ever been under an Intertek certification program.Intertek, Inc.3933 US Route 11, Cortland, NY 13045 USATelephone: 1 607-753-6711 Fax: 1 607-756-9891 Web: www.intertek.com
INTERTEK TEST DATA SHEETSPage 2 of 7Client/Ref #: Winola IndustrialEngineer:Andrew RulisonJob No.:G103218967Tested By:Matthew StevensProduct:Ladder PoleReviewed By: Andrew RulisonModel ASSE Z359.1-2007TRANSCRIBED TEST DATASample Control No: Client brought samples 9/6/17TEST EQUIPMENTUsed for TestXXParagraph4.3.6DescriptionManufacturerLoad CellInterfaceLatest Standards Used:Control No.Model No.Serial No.M3797NANAANSI/ASSE Z359.1-2007Test DescriptionResultsCal. Due2/20/18MSPass/FailAnchorage Connector Qualification Test (test section 4.3.6)*Ladder Frame4.3.6Cal. Date2/20/17Verified By:3,600 lbs-f & hold for 1-minute, thenrelease load and reapply 5,000 lbs-fand hold for NO1NONO1NONOPASSSample taken to breaking point on “Tie Off”anchor after testing. Broke @ 7853 lbs.*Tie-Off Anchor Clip4.3.63,600 lbs-f & hold for 1-minute, thenrelease load and reapply 5,000 lbs-fand hold for NO2NONO2NONOPASSSample taken to breaking point on “Tie Off”anchor after testing. Broke @ 8133 lbs.*Sample Tested with ½” Gap onLower Clip per client request.4.3.63,600 lbs-f & hold for 1-minute, thenrelease load and reapply 5,000 lbs-fand hold for ONOOrientationDeformation(3600)Breakage2NONOSample taken to breaking point on “Tie Off” anchor aftertesting. Broke @ 8581 lbs.
INTERTEK TEST DATA SHEETSClient/Ref #: Winola IndustrialEngineer:Andrew RulisonJob No.:G103218967Tested By:Matthew StevensProduct:Ladder PoleReviewed By: Andrew RulisonModel No.:HCL-PGE-2BStandard:Sample Control No: Client brought samples 9/6/17ANSI/ASSE Z359.1-2007TRANSCRIBED TEST DATAOrientation 1 (Around Frame)Page 3 of 7Date:9/6/17Date:9/7/17
INTERTEK TEST DATA SHEETSClient/Ref #: Winola IndustrialEngineer:Andrew RulisonJob No.:G103218967Tested By:Matthew StevensProduct:Ladder PoleReviewed By: Andrew RulisonModel No.:HCL-PGE-2BStandard:Sample Control No: Client brought samples 9/6/17ANSI/ASSE Z359.1-2007TRANSCRIBED TEST DATAOrientation 2 (Tie-Off Anchor Clip)Page 4 of 7Date:9/6/17Date:9/7/17
INTERTEK TEST DATA SHEETSClient/Ref #: Winola IndustrialEngineer:Andrew RulisonJob No.:G103218967Tested By:Matthew StevensProduct:Ladder PoleReviewed By: Andrew RulisonModel No.:HCL-PGE-2BStandard:Sample Control No: Client brought samples 9/6/17ANSI/ASSE Z359.1-2007TRANSCRIBED TEST DATA½’’ Gap on Lower ClipPage 5 of 7Date:9/6/17Date:9/7/17
INTERTEK TEST DATA SHEETSClient/Ref #: Winola IndustrialEngineer:Andrew RulisonJob No.:G103218967Tested By:Matthew StevensProduct:Ladder PoleReviewed By: Andrew RulisonModel No.:HCL-PGE-2BStandard:Sample Control No: Client brought samples 9/6/17ANSI/ASSE Z359.1-2007TRANSCRIBED TEST DATASample(s) Breaking PointPage 6 of 7Date:9/6/17Date:9/7/17
INTERTEK TEST DATA SHEETSClient/Ref #: Winola IndustrialEngineer:Andrew RulisonJob No.:G103218967Tested By:Matthew StevensProduct:Ladder PoleReviewed By: Andrew RulisonModel No.:HCL-PGE-2BStandard:Sample Control No: Client brought samples 9/6/17ANSI/ASSE Z359.1-2007TRANSCRIBED TEST DATAPage 7 of 7Date:9/6/17Date:9/7/17
Static Strength (Ladder Pole) 9/6/17 4.3.6 PASS Static Strength (Welded Clip) 9/6/17 4.3.6 PASS Please see attached test data for details. This test report concludes the work anticipated in the testing phase of your project. If there are any questions regarding this report please contact the undersigned at 607-753-6711.