Product Data SheetRXPS-002516, Rev AJanuary 2021Roxar 2600 MPFMMultiphase Flow Meter with Rapid Adaptive Measurement As oil and gas operators worldwide adjust their production methodologies and target more challengingreservoirs, the multiphase flow metering technology must be robust and reliable in ever more demandingconditions.The Roxar 2600 MPFM key features: Real time, three-phase measurement without the need for separation Modular design and selectable advanced software features to fit your application needs Flexible and adaptable configuration options throughout the lifetime of your field Intuitive and user-friendly operator interface tool for calibration and configuration The Roxar Rapid Adaptive Measurement embedded software supporting automation and trustworthymeasurement in dynamic multiphase flow Fully compatible with Emerson Connected Services, giving operators continuous access to Emersonexpertise and support The Roxar Multiphase Salinity System (RMSS) available as an additional module, providing live salinitycontent information when operating in water-dominant flow

Roxar 2600 MPFMJanuary 2021Roxar 2600 Multiphase Flow Meter model options andspecificationsEmerson offers a modular approach to the Roxar 2600 Multiphase Flow Meter. This makes it possible for operators to select onlythe modules suitable for their application and measurement needs, fully confident changes can be made in field if applicationneeds change over time.ModeldescriptionMMVMVGKey raw datameasurements:Base model – impedancemeasurementM model plus dP over venturimeasurementMV model plus gamma densitymeasurementApplicationdescription:Single well applicationsDirect well head monitoring andtrending of oil, water and gasfractions and ratesSingle well applicationsFlow rates for oil, water and gasover a broader range ofapplicationsSingle or multi-well applicationsFlow rates for oil, water and gasover a full range of applicationsOperating range: 0 - 85% gas volume fraction(GVF) 0 - 85% GVF and 95 - 100% GVF 0 - 100% GVF 0 - 100% WLR 0 - 100% WLR Flow velocity 1 - 40 m/s Flow velocity 1 - 40 m/s 0 - 100% water liquid ratio(WLR) Flow velocity 5 - 25 m/sMechanical specificationCategorySpecification descriptionInstallationVertical with upwards flowMeter sizesID 1½ in (35 mm) to ID 8 in (173 mm)Design pressureUp to 5,000 psi (345 bar)Design temperature-4 F (-20 C) to 266 F (130 C)Meter body wetted partsmaterial optionsDuplex UNS S31803Stainless steel UNS S31600Super duplex UNS S32760Inconel 625 UNS N06625PEEK naturalFlange connectionANSI flanges or hubs with clamp connectorsDensity measurement(when applicable)Compact gamma systemSource: Cs-137, 2, 5 or 8.3 mCiHalf-life 30.1 years2www.Emerson.com/Roxar

Roxar 2600 MPFMJanuary 2021Communication and electrical specificationCategorySpecification descriptionPower supply18 - 30 VDC100 - 240 VACPower consumption: 22 WCommunications interfaceRS-232RS-485EthernetCommunications protocolModbus RTUModbus TCPHTTPFlow computer mountingPainted aluminum Ex d housing for hazardous areaSS 316L Ex d housing for hazardous areaSS 316L IP 66 housing for safe areaRack mountable arrangement for safe areaStandards and certificationsCategoryStandard or certification descriptionHazardous area certificationATEXIECExCSA C/USTR CU 012 (EAC)Design codeASME B16.5 & ASME B31.3Material specification complianceASME B31.3Sour service wetted partsNACE MR 0175ISO 15156www.Emerson.com/Roxar3

Roxar 2600 MPFMJanuary 2021Measurement uncertainty specificationGVF rangeGas rates (%rel)Repeatability 25%25-90%90-95%95-98% 98%7.0%5.0%5.0%5.0%5.0%¼ of %¼ of %¼ of %Liquid rates (%rel)3.0%3.5%5.0%8.0%10%(1)Water-liquid ratio (%abs)2.0%2.5%3.5%4.0%10%(1)1. Uncertainties given at a 95% confidence interval.2. Applicable for operating pressures above 73 psi (5 bar).3. For non-gamma installations, the uncertainty figures are multiplied by 1.2 up to 85% GVF. For GVF above 85%, consult yourlocal Emerson representative.4. M-version uncertainties are 10% relative on gas and liquid rates and 5% absolute on WLR.(1)As the liquid fraction approaches zero, the uncertainties increase beyond this figure and a case-by-case calculation can be conducted.Software featuresThe Roxar 2600 Multiphase Flow Meter comes with the Rapid Adaptive Measurement core software as standard. Several value-addfeatures are available to optimize for application requirements.StandardFeaturesFunctionalityCoreOne modeAdaptive density measurementParallel computationBasic alarms and diagnosticsEmbedded PVTAdvanced Advanced PVTMultistage flashingGas lift integrationDetect and correctIn-situ flow verificationIn-situ calculation verificationIn-situ sensor verificationLayer compensationNon-gammaMultiphase non-gammaWetgas non-gammaConnect4Performance monitoringwww.Emerson.com/Roxar

January 2021Roxar 2600 MPFMRoxar 2600 MPFM MVGMeter Sizes: ID 1½ in (35 mm) to 4 in (87 mm)Flange Connection: ANSI flangesDesign Pressure: 3750 psi (258 bar)Meter Sizes: ID 2 in (50 mm) to 8 in (173 mm)Flange Connection: Hubs with clamp connectorsDesign Pressure: 5000 psi (345 bar)www.Emerson.com/Roxar5

Roxar 2600 MPFMJanuary 2021Roxar 2600 MPFM MVMeter Sizes: ID 1½ in (35 mm) to 4 in (87 mm)Flange Connection: ANSI flangesDesign Pressure: 3750 psi (258 bar)Meter Sizes: ID 2 in (50 mm) to 8 in (173 mm)Flange Connection: Hubs with clamp connectorsDesign Pressure: 5000 psi (345 bar)6www.Emerson.com/Roxar

January 2021Roxar 2600 MPFMRoxar 2600 MPFM MMeter Sizes: ID 2 in (50 mm) and 3 in (67 mm)Flange Connection: ANSI flangesDesign Pressure: 3750 psi (258 bar)www.Emerson.com/Roxar7

RXPS-002516Rev. AJanuary 2021Emerson Automation SolutionsRoxarGamle Forusveien 174031 StavangerNorwayEurope: 47 51 81 8800Russian CIS countries: 7 495 504 3405Emerson Automation SolutionsNorth America: 1 281 879 2328Latin America:Mexico: 52 55 5809 5010Argentina: 54 11 4809 2700Brazil: 55 15 3413 8000Chile: 56 2 2928 4800Peru 51 m 2021 Roxar AS. All rights reserved.The Emerson logo is a trademark and service mark of Emerson Electric Co. Roxar is a trademark ofRoxar AS. All other marks are property of their respective owners.Roxar supplies this publication for informational purposes only. While every effort has been made toensure accuracy, this publication is not intended to make performance claims or processrecommendations. Roxar does not warrant, guarantee, or assume any legal liability for the accuracy,completeness, timeliness, reliability, or usefulness of any information, product, or process describedherein. All sales are governed by our terms and conditions, which are available on request. Wereserve the right to modify or improve the designs or specifications of our products at any timewithout notice. For actual product information and recommendations, please contact your localRoxar representative.Roxar products are protected by patents. See ar-home/roxar-patents for details.Emerson Automation SolutionsAsia Pacific: 60 3 5624 2888Australia: 61 8 9208 1600Middle East: 971 4811 8100

Roxar 2600 Multiphase Flow Meter model options and specifications Emerson offers a modular approach to the Roxar 2600 Multiphase Flow Meter. This makes it possible for operators to select only the modules suitable for their application and measurement needs, fully confident changes can be made in field if application needs change over time. Model