
Transcription
Locator Component ListingThe Self-Aligning feature of the LOCATOR attachment system allows a patient to easily seat theiroverdenture without the need for accurate alignment of the attachment components.The unique Dual Retention innovation provides the LOCATOR attachment with greater retentionsurface area than ever available before with other attachments.Durability tests have proven the LOCATOR’s incredible wear resistance and long lasting performancefor over 110,000 insertion cycles.The LOCATOR Male pivots in its permanent metal denture housing for a genuine resilient connectionof the prosthesis. The retentive nylon male remains in static contact with the female socket while itsmetal denture cap has a full range of rotational movement over the male. This design of the pivotingLOCATOR Male allows a resilient connection for the overdenture without any resulting loss ofretention.The LOCATOR attachment is a supra-radicular design that gives you the choice of a straight post, twoangles (10 and 20 degrees) to accommodate divergent roots and a special Cast-to version.Plus seven different retentive males allow for your choice of regular retention (white),strong anglecorrection (green), light retention (pink), light angle correction (orange), extra-light retention (blue),light angle correction (red), and zero retention (grey) according to the needs of the patient. Count onPREAT Corporation for all your Locator Abutment and Attachment needs.Locator Component Listing9015 – LOCATOR MODEL – IMPLANT (external hex)Full lower overdenture with two endosseous external heximplants and Locator implant attachments. All DEMOmodels are sold at our manufacturing costs.
9006 – LOCATOR MODEL – IMPLANT (internal hex)Full lower overdenture with two endosseous internal heximplants and Locator implant attachments. All DEMOmodels are sold at our manufacturing costs.9014 – LOCATOR MODEL – ROOTFull Lower Overdenture with Two Cuspids Roots withLOCATOR Root attachments. All DEMO models are soldat our manufacturing costs.Buy it Now8393 – Locator Core ToolThis 3-in-1 tool contains: The Male Removal Tool Male Seating Tool andGold-Plated Implant Abutment DriverThis tool is required for placement procedure of allLocator Root Attachments and Locator ImplantAbutments. 8397 – Locator Male Removal ToolThe Male Removal Tool is used to remove the nylon malefrom the metal denture cap. The sharp circular edge of theremoval tool should be wedged tightly down into the verybottom of the plastic male so that it will catch the inside ofthe plastic insert and pull it at an angle out of the metalhousing. Prior to use, loosen the tip a full 3 turns counterclockwise (you will see a visible gap).
To discard the nylon male from the tip of the Core Tool; point the tool down and away from you andtighten the Male Removal Tool clockwise back onto the Core Tool. This will activate the removal pinand dislodge the nylon male from the tip end.8390 – LOCATOR Abutment DriverThe LOCATOR Abutment Driver is a special gold plated driverdesigned to engage the inside diameter of the LocatorAbutment and thread it into the implant.Please Note: A .050 (1.25mm) Hex Torque Wrench Driver Tipwill fit into the backside of the LOCATOR Abutment Driver tohelp achieve the minimum seating force of 20N-cm.8394 – LOCATOR Abutment DeliverySleeveThe Locator Abutment Delivery Retaining Sleeve is designedfor use with the #8390 driver/#8393 Core tool when taking anabutment to the mouth. Strongly reduces chance ofabutment falling “out” of the driver tool.The Abutment Holder Sleeves can be sterilized for reuseapproximately 5 times before losing retention and needing to be replaced. Package of 4 and Packageof 20.4391 – LOCATOR TORQUE WRENCHTool kit is used for tightening LOCATOR abutments to therecommended torque of minimum 20 Newton Centimeters.Kit contains: 20 Ncm Torque Wrench, LOCATOR Driver Insert(15mm) (8926), and Thumb Knob Wrench. All components arestainless steel and very easy to maintain and sterilize byeither autoclave or chemclave.9020 – LOCATOR TORQUE WRENCHTool kit is used for tightening LOCATOR abutments to 30Newton Centimeters.Kit contains: 30Ncm Torque Wrench, 15mm Locator InsertDriver and a Thumb Knob Wrench. All components arestainless steel and very easy to maintain and sterilize by eitherautoclave or chemclave
Buy it Now8260 – LOCATOR 35NCM TORQUEWRENCH INSERT DRIVER (15MM)For use with Straumann torque wrenches.Buy it Now8280 – LOCATOR 35NCM TORQUEWRENCH INSERT DRIVER (21MM)For use with Straumann e torque wrenches.Buy it Now8913 – LOCATOR INSERT DRIVER(LATCH-TYPE CONNECTION)23mm total length. This driver goes direct from a latch-typeconnection torque wrench to the LOCATOR Implant Abutmentand allows direct torque tightening of the LOCATOR ImplantAbutments.Compatibles: 3i Implant Innovations, Nobel BioCare, and Thommen Medical.Buy it Now8914 – LOCATOR INSERT DRIVER(LATCH-TYPE CONNECTION)29mm total length. This driver goes direct from a latch-typeconnection torque wrench to the LOCATOR Implant Abutmentand allows direct torque tightening of the LOCATOR ImplantAbutments.Compatibles: 3i Implant Innovations, Nobel BioCare, and Thommen Medical.
Buy it Now8926 – LOCATOR TORQUE WRENCHDRIVER (SQUARE DRIVE CONNECTION)15mm total length. This driver goes direct from a square driveconnection torque wrench to the LOCATOR Implant Abutmentand allows direct torque (minimum 20 Ncm) tightening of theLOCATOR Implant Abutments.Compatibles: Zest Anchors, Astra Tech, Bio-Horizon, Lifecore, Innova, and Zimmer.8927 – LOCATOR TORQUE WRENCHDRIVER (SQUARE DRIVE CONNECTION21mm total length. This driver goes direct from a latch driveconnection torque wrench to the LOCATOR Implant Abutment andallows direct torque (minimum 20 Ncm) tightening of the LOCATORImplant Abutments.Compatibles: 3i Implant Innovations, Steri-Oss, and Thommen Medical.4609 – .050 (1.25MM) HEX DRIVER FORLATCH CONNECTION.050 Hex Driver (Latch Drive Connection) for the Torque WrenchKit.Buy it Now4936 – .050 (1.25MM) HEX INSERTDRIVER FOR TORQUE WRENCH.050 Hex Driver (Square Drive Connection) for the Torque WrenchKit.Buy it Now
8924 – Locator Pilot Drill6mm x 1.8mm Diameter with Plastic Depth Reference Ring. Foruse with 8520, 8521, 8522, and 8528 Locator femalesAlso Order: Locator Spotface Diamond Bur (8922)Buy it Now8922 – Locator Spotface Diamond BurCountersink drill creates the minimal cementation surfacepossible on the root. For use with 8520, 8521, 8522, and 8528Locator femalesAlso Order: Locator Pilot Drill (8924)Buy it Now9102 – 1.7mm Bar Drill (2.0mm Thread)1.7mm Bar Drill (2.0mm Thread) indicated for use with theLOCATOR Bar Female (8589). Also order: 2.0mm Bar Tap (9104)Buy it Now9103 – Locator 1.8mm Bar Drill (2-56Thread)1.8mm Bar Drill (2-56Thread) indicated for use with the LOCATORBar Female (8587).Also order: 2-56 Bar Tap (2-56 Thread)(9105)Buy it Now9104 – 2.0mm Bar Tap2.0mm Bar Tap (2.0mm Thread) indicated for use with theLOCATOR Bar Female (8589) and 1.7mm Bar Drill.Buy it Now
9105 – 2-56 Bar Tap (2-56 Thread)2-56 Bar Tap indicated for use with the LOCATOR Bar Female(8587)(2-56 Thread) and 1.8mm Bar Drill (9103).Buy it Now8014 – Threaded Castable Sleeve(2.0MM)2.0mm Delrin Castable Threaded Insert (10 pack) makes iteven easier to create a threaded site in an implant bar foraccepting the threaded LOCATOR Bar Female (8589). AlsoOrder: LOCATOR Bar Female (8589), 2.0mm Bar Tap (9104)and Drill & Tap Holder (8016)8013 – Threaded Castable Sleeve (2-56THREAD)2.0mm Delrin Castable Threaded Insert (10 pack) makes it eveneasier to create a threaded site in an implant bar for acceptingthe threaded LOCATOR Bar Female (8587). Also Order:LOCATOR Bar Female (8587), 2-56mm Bar Tap (9105) and Drill& Tap Holder (8016)9107 – Locator Paralleling Mandrel forBar FemaleThe LOCATOR Paralleling Mandrel is indicated for all Laser BarFemales (8588 & 8590) and is used in a surveyor to place the LaserBar Female into position.Buy it Now8517 – Locator Parallel Post (4 pack)LDPE (Black), Locator Parallel Post may be used as a handle whenseating female and to visualize parallel alignment of multipleattachments.
Buy it Now8016 – Drill and Tap HolderMade to fit into the handpiece of a milling unit in the dentallaboratory, the tool has set screws for holding the LOCATOR BarDrill and then the LOCATOR Bar Tap in place while performing anexact parallel preparation (means less chance of breaking a tap).Buy it Now1747 – Locator Retrofit Kit (2) for WornERA Root AttachmentsIncludes 2 LOCATOR Retrofit Females, 2 Parallel Posts, and 2Weep Hole Alignment Pins. Please order Locator malesseparately. New Locator female and male only requires anadditional 0.32mm of inter-occlusal space!8520 – Locator 0º Degree Female (2pack)Extra-Radicular Design. Stainless Steel with TiN coating.Female root attachment extends above the root plane1.5mm. Diameter 4.0mm with contact face 3.75mm and postextension 6.0mm x 1.8mm. Post may be shortened in lengthto 3.0mm if desired. Width of root surface must equal or exceed 4.0mm. Save 10% and order 8520-10 (5 packs of 2) Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P 0.045 (max), S 0.030 (max),Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N 0.100 (max). TiN Coating (Titanium Nitride): Titanium/Argon/Nitrogen 99% pure8521 – Locator 10º Degree Female (2pack)Extra-Radicular Design. Root Angled Correction. Stainless Steel withTiN coating. Diameter 4.0mm with contact face 3.75mm and post
extension 6.0mm x 1.8mm. Post may be shortened in length to 3.0mm if desired. Width of root surface must equal or exceed 4.0mm. Save 10% and order 8521-10 (5 packs of 2) Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P 0.045 (max), S 0.030 (max),Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N 0.100 (max). TiN Coating (Titanium Nitride): Titanium/Argon/Nitrogen 99% pure8522 – Locator 20º Degree Female (2pack)Extra-Radicular Design. Root Angled Correction. Stainless Steelwith TiN coating. Diameter 4.0mm with contact face 3.75mm andpost extension 6.0mm x 1.8mm. Post may be shortened in lengthto 3.0mm if desired. Width of root surface must equal or exceed 4.0mm. Save 10% and order 8522-10 (5 packs of 2) Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P 0.045 (max), S 0.030 (max),Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N 0.100 (max). TiN Coating (Titanium Nitride): Titanium/Argon/Nitrogen 99% pure8528 – Locator Cast-to Female (2 pack)Extra-Radicular Design. Stainless Steel with 3.Ommx 1.8mm Øpost extension, assembled with parallel post. Please refer to LocatorRoot Attachment System Technique for instructions. Also available inLocator Coping Kit (8051/8050).IMPORTANT NOTE: Do not allow the casting temperature to raise above 2000 F which will melt thestainless steel female. Do not use a bur to remove investment, sandblasting with aluminum oxide, oran acid pickling solution, can damage the internal socket of the female attachment. Do NOT shortenthe threaded retention post. 8922 and 8924 drills must be used. Save 10% and order 8528-10 (5 packs of 2) Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P 0.045 (max), S 0.030 (max),Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N 0.100 (max).Buy it Now
8586 – Locator Cast-to Bar Female (2Pack)Stainless Steel. Indicated for casting-to a LOCATOR Bar Female intoa gold alloy bar.IMPORTANT NOTE: Do not allow the casting temperature to raiseabove 2000 F which will melt the stainless steel female. Do not usea bur to remove investment, sandblasting with aluminum oxide, or an acid pickling solution, candamage the internal socket of the female attachment Save 10% and order 8586-10 (5 packs of 2) Metal content, 316L Stainless Steel: C 0.030 (max), Mn 2.00 (max), P 0.045 (max), S 0.030 (max),Si 1.00 (max), Cr 16-18% , Ni 10-14%, Mo 2-3%, N 0.100 (max). Also order: LOCATOR Paralleling Mandrel for Bar Female (9107).8587 – Locator Bar Female (2-56 Thread)(2 Pack) Titanium alloy with TiN coating. LOCATOR Bar Female designed in a special thread size to replaceworn out TSB Ball Attachments. The only requirement is a minimumbar width of 4mm to upgrade with a LOCATOR. Also order: 1.8mm Bar Drill (2-56 Thread)(9103) and 2-56 Bar Tap(2-56 Thread)(9105) Save 10% and order 8587-10 (5 packs of 2)8588 – Locator Laser Bar Female,Titanium (2 Pack) Titanium alloy with TiN coating. Indicated for use withmilled titanium bars. Also order: Paralleling Mandrel (9107) and extraBlock-Out Spacers (8514) Save 10% and order 8588-10 (5 packs of 2)Buy it Now
8589 – Locator Bar Female (2.0mmThread) (2 Pack) Titanium alloy with TiN coating. For total retrievability you can simply drill, tap, and thread the newLOCATOR Bar Female into your completed implant bar. Also Order: 1.7mm Bar Drill (2.0mm Thread)(9102) and 2.0mm Bar Tap (2.0mm Thread)(9104).The 1.7mm Bar Drill and a 2.0mm Bar Tap are used for creating the threaded site into either atitanium bar or cast alloy bar. Save 10% and order 8589-10 (5 packs of 2)8590 – Locator Laser Bar Female,Stainless Steel (2 Pack) Stainless steel and indicated for laser welding to a cast goldalloy bar. Also order: LOCATOR Paralleling Mandrel for Bar Female(9107) and extra Block-Out Spacers (8514). Save 10% and order 8590-10 (5 packs of 2)8516 – LOCATOR FEMALE ANALOG(5MM DIAMETER) (4 PACK)Aluminum. Locator Root Analog. Also used with Straumannand wide platform implant systems.Also Order: Locator Impression Coping (8505)Save 10% and order 8516-20 (5 packs of 4)Buy it Now8530 – LOCATOR FEMALE ANALOG(4MM DIAMETER) (4 PACK)Aluminum. Locator Female Analog (4mm) for regular andnarrow platform implant systems.Also Order: Locator Impression Coping (8505)Save 10% and order 8530-20 (5 packs of 4)Buy it Now
8505 – LOCATOR IMPRESSION COPING (4 PACK) Aluminum Housing with Black Locator LDPE Male (6.1mm height).The Locator Impression Coping is designed with minimum retentionto be picked up with the impression material in a tray. For Reline Impression with a denture use Locator Denture Cap withBlack Processing Male for lower profile space requirement. Also Order: Locator 5mm Diameter Analog (8516) or Locator 4mm Diameter Analog (8530). Save 10% and order 8505-20 (5 packs of 4)8510 – LOCATOR DENTURE CAP WITH PROCESSING MALE (4PACK) Titanium Denture Cap with Black Processing Male Save 10% and order 8510-108028 – LOCATOR BAR PROCESSING PACKAGE (2 PACK) Includes: Denture Cap with Yellow Bar Processing Male,White Nylon Male (5lbs), Pink Medium Retention Nylon Male(3lbs), Blue Light Retention Male (1.5lbs), and Block-Out Spacer (4). Save 10% and order 8028-10 (5 packs of 2)Buy it Now8540 – LOCATOR EXTENDED RANGE MALE PROCESSINGPACKAGE (2 PACK) TIIncludes: Titanium Denture Cap with Black Processing Male,Red Male (0.5-1.0lbs), Orange Male (2.0lbs), Green RetentionMale (3.5-4.0lbs), and Block-Out Spacer.Save 10% and order 8540-10 (5 packs of 2)
8519 – LOCATOR MALE PROCESSING PACKAGE (2 PACK) TIIncludes: Titanium Denture Cap with Black Processing Male,White Nylon Male (5lbs), Pink Medium Retention Nylon Male(3lbs), Blue Light Retention Male (1.5lbs), and Block-Out Spacer.Save 10% and order 8519-10 (5 packs of 2)8550 – LOCATOR MALE PROCESSING PACKAGE (2 PACK) SSIncludes: Stainless Steel Denture Cap with Black Processing Male,White Nylon Male (5lbs), Pink Medium Retention Nylon Male(3lbs), Blue Light Retention Male (1.5lbs), and Block-Out Spacer.Designed for laser welding to cast frameworksSave 10% and order 8550-10 (5 packs of 2)Buy it Now8559 – LOCATOR REPLACEMENT MALE PURPLE PURPLE (4 PACK) 8lbs Extra Strong Retention Replacement Purple Nylon Male (8lbs) usedwith LOCATOR Male Denture Cap.8524 – LOCATOR REPLACEMENT MALE WHITE WHITE (4 PACK) 5lbs Strong Retention Replacement White Nylon Male (5lbs) used withLOCATOR Male Denture Cap. Save 10% and order 8524-20 (5 packs of 4)8527 – LOCATOR REPLACEMENT MALE PINK PINK (4 PACK) 3lbs Medium Retention Pink Nylon Replacement Male (3lbs) used withLOCATOR Male Denture Cap. Save 10% and order 8527-20 (5 packs of 4)
8529 – LOCATOR REPLACEMENT MALE BLUE BLUE (4 PACK) 1.5lbs Light Retention Blue Nylon Replacement Male (1.5lbs) used withLOCATOR Male Denture Cap.Save 10% and order 8529-20 (5 packs of 4) Buy it Now8547 – Locator Replacement Male Extended Range Green GREEN (4 PACK) 3.5-4.0lbs The Extended Range Replacement Male standard (green 3.5-4lbs)can accommodate divergent abutments up to 20º (40º betweenmultiple abutments) Save 10% and order 8547-20 (5 packs of 4)8915 – LOCATOR REPLACEMENT MALE EXTENDED RANGE ORANGE ORANGE (4 PACK) 2.0LBS The Extended Range Replacement Male light retention (orange 2lbs) can accommodate divergent abutments up to 20º (40º betweenmultiple abutments) Save 10% and order 8915-20 (5 packs of 4)8548 – Locator Replacement Male Extended Range Red RED (4 PACK) 0.5LBS The Extended Range Replacement Male extra light (red 0.5lbs)can accommodate divergent abutments up to 20º (40º betweenmultiple abutments) Save 10% and order 8548-20 (5 packs of 4)8558 – Locator Replacement Male Zero Gray GRAY(4 PACK) 0 LBS The Extended Range Replacement Male ZERO can accommodatedivergent abutments up to 20º (40º between multiple abutments) Save 10% and order 8558-20 (5 packs of 4)
8515 – Locator Black Processing Male (4 Pack) Processing Black LDPE Male to be used with the Locator DentureCap (8519) or Locator Impression Coping (8505) during relines,impressions, and direct processing of males 1-1.5 lbs of retention, but these processing males do not provideany of the resiliency of the final Locator males or last very long in themouth. Save 10% and order 8515-20 (5 packs of 4)8026 – Locator Bar Yellow Processing Male (4 Pack) Processing Yellow LDPE Male to be used with the Locator DentureCap (8519) or Locator Impression Coping (8505) during relines,impressions, and direct processing of Locator Attachments on BARS. 1-1.5 lbs of retention, but these processing males do not provideany of the resiliency of the final Locator males or last very long in themouth Save 10% and order 8026-20 (5 packs of 4)8569 – Locator Processing Spacer (4Pack) Processing Male to be used by Laboratory when processingto create space in denture for chairside pickup. Using the processing males eliminates the need for thedentist to relieve the denture when direct pickup of the males isindicated.6.35mm diameter, 3.3mm heightSave 10% and order 8569-20 (5 packs of 4) 8514 – Locator Block Out Spacer (20Pack)White Block-Out Spacer is placed over the Locator Root orImplant Abutment and is used to block out the areaimmediately surrounding the abutment.For more information, contact Preat at 1-800-232-7732 orvisit preat.com
implants and Locator implant attachments. All DEMO models are sold at our manufacturing costs. 9006 - LOCATOR MODEL - IMPLANT (internal hex) . Steri-Oss, and Thommen Medical. 4609 - .050 (1.25MM) HEX DRIVER FOR LATCH CONNECTION .050 Hex Driver (Latch Drive Connection) for the Torque Wrench Kit. Buy it Now 4936 - .050 (1.25MM) HEX INSERT