VIAVI SolutionsQuick CardT-BERD /MTS-5800 Network TesterEthernet RFC 2544 Layer 3 TrafficThis document outlines how to configure and run an RFC 2544 Layer 3 Traffic Test for Metro EthernetService Activation. A second T-BERD/MTS 5800 or compatible loopback device should be used at thefar-end of the line under test for traffic loopback.Equipment Requirements: T-BERD/MTS-5800 equipped with thefollowing:o BERT software release V27.0 or greatero Ethernet test options: C510M1GE for 1 Gigabit or less C510GELAN for 10 Gigabit Ethernet C525GELAN for 25 Gigabit Ethernet C540GELAN for 40 Gigabit Ethernet C5100GELAN for 100 GigabitEtherneto SFP, QSFP, or CFP4 optical transceiverto match the line under test Patch Cords to match the T-BERD/MTSoptics and the line under test Fiber optic inspection microscope (VIAVIP5000i or FiberChek Probe)Fiber Optic Cleaning suppliesFigure 1: Equipment RequirementsThe following information is required to complete the test: Physical Interface (10/100/1000BASE-T, 1000BASE-LX, 10GBASE-LR, 100GBASE-LR4, etc.) Auto Negotiation settings of the port under test VLAN ID, if VLAN tagging is used IP Address Parameters (DHCP or Static, Source IP, Default Gateway, Subnet Mask, andDestination IP)Fiber Inspection Guidelines: All fiber end-faces must be clean and passan inspection test prior to connection. Use the VIAVI P5000i, FiberChek Probe, orSidewinder microscope to inspect both sidesof every connection being used (SFP Port,bulkhead connectors, patch cords, etc.)Figure 2: Inspect Before You Connect

VIAVI SolutionsConnect to Fiber Under Test (FUT):1. For copper 10/100/1000BASE-T interfacetesting with the T-BERD/MTS 5800v2,connect the Port 1 10/100/1000 RJ-45 jackto the port under test using CAT 5E orbetter cable.2. For copper 10/100/1000BASE-T interfacetesting with the T-BERD/MTS 5800-100G,insert a copper SFP into the Port 1SFP /SFP28 slot and connect to the portunder test using CAT 5E or better cable.3. For optical interfaces: Insert SFP, QSFP, or CFP4 compatiblewith your physical interface into thePort 1 slot on the top of the test set. Inspect and, if necessary, clean allfibers and bulkheads, as described onpage 1. Connect the SFP, QSFP, or CFP4 to theport under test using a Single Mode orMultimode jumper cable compatiblewith the interface under test.Figure 3: T-BERD 5800v2 Dual Port mainframeFigure 4: T-BERD 5800-100G mainframeLaunch Test:1. Press the Power buttonto turn on the test set and view the startup screen.2. Using the Select Test menu, Quick Launch menu, or Job Manager, launch an Ethernet, RFC 2544, L3Traffic, Terminate test on port 1 for the desired physical interface. For example:Ethernet 10/100/1000 RFC 2544 L3 Traffic P1 Terminate.Figure 5: Startup Screen

VIAVI Solutions3. Tap thebutton next to“Start a New Configuration (reset todefaults)”Figure 6: RFC 2544 testConfigure Test:1. Tap thebutton to display theL2 Network Settings screen. If you aretesting a VLAN, set Encapsulation to VLANand enter your VLAN ID.Figure 7: L2 Network Settings – Local2. Tap thebutton to display theRFC 2544 Test: L3 Networks Settings Local screen.3. Enter IP Parameters (Source IP Type,Source IP, Default Gateway, SubnetMask, and Destination IP). The TBERD/MTS will resolve the destination IPaddress using the Address ResolutionProtocol (ARP). Once resolved, thebutton becomes available andyou can use it to verify connectivity to thefar-end loopback device.Figure 8: L3 Network Settings: Local4. Tap thebutton twice todisplay the RFC 2544 Test: Select Testsscreen.5. Select the Throughput, Latency, FrameLoss, Packet Jitter, and Burst Test Tests.Figure 9: Select Tests

VIAVI Solutions6. Tap thebutton to display theRFC 2544 Test: Utilization screen. Set MaxBandwidth to the Committed InformationRate (CIR).Figure 10: Utilization7. Tap thebutton to display theRFC 2544 Test: Frame Lengths screen.Select the 1st, 4th, and 8th Frame Lengths.If the MTU is greater than 1518 (1522 withVLAN), also enter and select the frame lengthof the MTU. Deselect (uncheck) all otherframe sizes.Figure 11: Frame Lengths8. Tap thebutton 3 times todisplay the RFC 2544 Test: Burst Test screen.Set CBS (kB) to the Committed Burst Size.Figure 12: Burst Test9. Tap thebutton twice to displaythe Test Ctls: Test Thresholds screen. Checkall boxes for which a Pass/Fail Threshold isknown. Enter the Threshold for eachselection.Figure 13: Test Thresholds

VIAVI SolutionsRun Test:1. Tap thebutton 3 times todisplay the Run J-QuickCheck screen. Tapthe Not what you want? link and check Testusing configured RFC2544 Max bandwidthbox, then tap Back to return to previousscreen.Tap thebutton.Verify that the Remote Loop is recognized,and that Measured Throughput is greaterthan or equal to the Committed InformationRate.Figure 14: Run J-QuickCheck2. Tap thebutton to display theRun RFC 2544 Tests screen.Tap thebutton.Wait for the test to complete and verify thatall tests pass or complete as indicated by agreen or blue checkmark.Figure 15: Run RFC 2544 Tests3. Tap thebutton three times todisplay the Report screen. Tap.4. Tap thebutton three times to closethe report and exit the RFC-2544 test.Figure 16: Create ReportContact Us 1 844 GO VIAVI( 1 844 468 4284)To reach the VIAVI office nearest you,visit viavisolutions.com/contacts. 2018 VIAVI Solutions Inc.Product specifications and descriptions in thisdocument are subject to change without notice.

with the interface under test. Figure 4: T-BERD 5800-100G mainframe Launch Test: 1. Press the Power button to turn on the test set and view the startup screen. 2. Using the Select Test menu, Quick Launch menu, or Job Manager, launch an Ethernet, RFC 2544, L3 Traffic, Terminate test on port 1 for the desired physical interface. For example: