RL-HPJHand Pallet Jack ScaleTechnical ManualMay 19, 2021PN 183812 Rev B
An ISO 9001 registered company Rice Lake Weighing Systems. All rights reserved.Rice Lake Weighing Systems is a registered trademark ofRice Lake Weighing Systems.All other brand or product names within this publication are trademarks orregistered trademarks of their respective companies.All information contained within this publication is, to the best of our knowledge, complete andaccurate at the time of publication. Rice Lake Weighing Systems reserves the right to makechanges to the technology, features, specifications and design of the equipment without notice.The most current version of this publication, software, firmware and all other productupdates can be found on our website:www.ricelake.com
ContentsContents1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.11.2Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22.0 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32.12.22.32.42.5Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indicator Stand Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Handlebar Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Printer Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .334553.0 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153.163.173.183.19Pallet Jack Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63.1.1Height Control Lever Positions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6General Use Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7The Indicator Display and Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9General Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Editing Numeric Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Weighing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113.6.1Power on the Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113.6.2Put the Pallet Jack in Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113.6.3Lift the Load and Read the Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Zero. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Regulation of the Display Brightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Automatic Tare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Tare Deletion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Preset Tare (Pt). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Print (and Reprint of the Last Ticket) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Tare Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153.16.1 Store a Tare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153.16.2 Retrieve a Stored Tare. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Automatic Tare Deletion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Number IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173.18.1 Enter the ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173.18.2 Enable Automatic ID Deletion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Date and Time (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184.0 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194.14.24.34.4Access the Function Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .High Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Accumulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.3.1Display Accumulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.3.2Reset Accumulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.3.3Print Accumulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Net Accumulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.4.1Accumulate the Net Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1920202121212222Technical training seminars are available through Rice Lake Weighing Systems.Course descriptions and dates can be viewed at www.ricelake.com/trainingor obtained by calling 715-234-9171 and asking for the training department. Rice Lake Weighing Systems All Rights Reservedi
RL-HPJ Hand Pallet Jack Scale4.4.2Briefly Display Total . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.4.3End and Reset Total . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.4.4Print and Reset Grand Total . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5 Piece Counting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5.1Sample and Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5.2Switch Between Piece and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5.3Average Piece Weight Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5.4Enter the Average Piece Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5.5Total Load Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.6 Check Weighing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.6.1Check Weighing with a Known Target Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.6.2Check Weighing with an Acquired Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.6.3Check Weighing Display Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.6.4Updating the Known Target Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.6.5Updating the Acquired Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.6.6Edit the Min and Max Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.7 Unit of Measurement Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.7.1Standard Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.7.2Conversion Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.8 Percentage Weighing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.8.1Percentage Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.8.2Percentage Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.9 Hold Weight Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.10 Display Net Weight and Gross Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.11 Metrological Information of the Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65.0 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . s the Configuration Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Save and Exit the Configuration Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Available Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Serial Menu (SERiAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Layout Menu (LAyovt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Filter Menu (FiLter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Screen Menu (SCreen) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery Menu (batt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Eco Battery Menu (ECo.bat) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Remote Menu (Remote) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Factory Configuration Reset (reset) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Diagnostics Menu (diaG). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Advanced Menu (aduanC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373737383942424242434344446.0 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 456.16.2Calibration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Complete Calibration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457.0 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 487.17.27.37.47.57.6Maintenance Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Scheduled Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Daily Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Regulation of the Forks Lowering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Oil Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FAQ - Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Rice Lake continually offers web-based video training on a growing selectionof product-related topics at no cost. Visit www.ricelake.com/webinarsiiVisit our website www.RiceLake.com484848495051
ContentsContents7.77.87.97.6.1Print . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.6.2Totalization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.6.3Tare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.6.4Weighing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.6.5Pieces Counting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Weighing Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Configuration Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51515152525353548.0 Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 569.19.2Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Technical training seminars are available through Rice Lake Weighing Systems.Course descriptions and dates can be viewed at www.ricelake.com/trainingor obtained by calling 715-234-9171 and asking for the training department. Rice Lake Weighing Systems All Rights Reservediii
RL-HPJ Hand Pallet Jack ScaleRice Lake continually offers web-based video training on a growing selectionof product-related topics at no cost. Visit www.ricelake.com/webinarsivVisit our website www.RiceLake.com
Introduction1.0IntroductionThe Pallet Jack Scale is ideal for handling and weighing pallets or standardized containers directly where they are located,saving time and money.The durable and precise Pallet Jack Scale is equipped with high performance weighing electronics and features amulti-functional program that helps perform daily tasks.Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.comWarranty information can be found on the website at www.ricelake.com/warranties1.1SafetySafety Signal Definitions:DANGERIndicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. Includeshazards that are exposed when guards are removed.WARNINGIndicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Includeshazards that are exposed when guards are removed.CAUTIONIndicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury.IMPORTANTIndicates information about procedures that, if not observed, could result in damage to equipment or corruptionto and loss of data.General SafetyDo not operate or work on this equipment unless this manual has been read and all instructions are understood.Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice LakeWeighing Systems dealer for replacement manuals.WARNINGFailure to heed could result in serious injury or death.This Pallet Jack Scale is designed to weigh exclusively on standardized pallets.Never load the scale beyond the maximum capacity stated on the plate of the weight readout instrument.Do not use the scale in environments where there is the danger of fire or explosion.Do not load the forks when they are raised, not even partially.Before using the pallet jack, ensure it is in working order.To achieve a correct weight, the forks need to be raised at least 2-4 inches to avoid the frame from rubbing against anything.Do not expose the Pallet Jack Scale to atmospheric agents (sun, rain, etc.).Use the Pallet Jack Scale in non-condensing environments with moderate temperature and humidity levelsUse the Pallet Jack Scale where there are no vibrations.Do not use of solvents or aggressive substances to clean the Pallet Jack Scale.Do not to make any modifications to the Pallet Jack Scale.Do not use the Pallet Jack Scale when it no longer fulfills the safety criteria.Do not use flammable products to clean the Pallet Jack Scale or the pallets.Do not subject the indicator to moisture.Anything not specifically described in this manual is considered improper use of the equipment. Rice Lake Weighing Systems All Rights Reserved1
RL-HPJ Hand Pallet Jack Scale1.2 FeaturesHeavy-gauge steel with a durable powder coat finishLarge 1'' tall, high contrast digits, which are clearly visible even in poor lighting conditions on a clear LCD displayWaterproof membrane keyboard with 17 functional keysConfiguration, calibration and diagnostics all from the indicator keyboardStandard 45.25'' (1150 mm) fork lengthStandard 26.75'' (680 mm) fork widthMaximum lifting height of the forks: 7.75'' (200 mm) from the groundHeight of completely lowered forks: 3.125'' (80 mm) from the groundPolyurethane steering wheels and double loading rollers offer greater stabilityFour stainless steel IP68 load cellsHandlebar with height control leverWeight indicator in IP65 stainless steel water-resistant enclosure, which is easy to clean and resistant to harsh andcorrosive environments Removable rechargeable battery and set-up for 24/7 continuous use kit or battery operation Rechargeable battery is removable and mounted on the pallet jack One month of operating time with typical non continuous use due to its programmable automatic power saving function(80 hours of operating time with continuous use)Handlebar withHeight Control LeverWeight IndicatorRechargeable BatterySteering Wheels3.15-3.35'' to 7.09-7.87''(80-85 mm to 180-200 mm)Loading CellsFigure 1-1. Pallet Jack Scale2Visit our website www.RiceLake.comLoading ForksDouble Load Wheels
Installation2.0InstallationThis section describes procedures for unpacking and assembly of the Pallet Jack Scale.2.1UnpackingImmediately after unpacking, visually inspect the Pallet Jack Scale to ensure all components are included and undamaged.The shipping carton should include the following:If any parts were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately. Fork Assembly Battery M8 Washers (3) Handlebar Charger M10 x 15 mm Screws (4) Indicator Stand M8 x 20 mm Screws (3) M10 Washers (4)Recommended Tools (Not Provided) 2.5 mm hex key 6 mm hex key 8 mm hex key2.2Indicator Stand AssemblyRefer to Figure 2-1 and the steps within this section to assemble the indicator stand to the main fork assembly.1. Cut the red zip tie holding the wire sleeve to the pallet jack chassis.2. Place the indicator stand on the fork assembly, being careful not to pull or pinch the load cell wires (Figure 2-1-A).Note The load cells of the pallet jack come wired to the indicator.3.4.5.6.7.Ensure the stand is properly supported and seated correctly.Feed excess wire sleeve up into the indicator stand.Remove the four screws that secure the front plate to the indicator stand using a 2.5 mm hex key.Secure indicator stand with four M10 x 15 mm screws and M10 washers using an 8 mm hex key (Figure 2-1-A).Reattach the front plate to the indicator stand, using the provided hex screws (4) (Figure 2-1-B).ABFigure 2-1. Indicator Stand Assembly Rice Lake Weighing Systems All Rights Reserved3
RL-HPJ Hand Pallet Jack Scale2.3Handlebar AssemblyFollow the steps within this section to assemble the handlebar to the main fork assembly.1. Remove the hex screws (3) from the steering column of the fork assembly using an 6 mm hex key (Figure 2-2-A).2. Place base of handlebar into the steering column of fork assembly then secure base of handlebar into the steeringcolumn of the fork assembly using the hex screws (3), removed in Step 1, using an 6 mm hex key (Figure 2-2-B).ABFigure 2-2. Handlebar Attachment3. Direct the handlebar chain into the handlebar and through the center hole in the pivot pin (Figure 2-3-A).4. Push down on the steering column lever and hold down to assist in joining the handlebar chain with the liftingconnection lever. Navigate the end of the chain into the groove in the lifting connection lever. Ensure the bottom catchof the chain is below the lever and seated completely into the groove for a good connection (Figure 2-3-B).5. Release the steering column lever, further engaging the handlebar chain with the connection lever (Figure 2-3-C).ABCFigure 2-3. Connecting the Handlebar Chain4Visit our website www.RiceLake.com
Installation2.4Battery InstallationRefer to Figure 2-4 and the steps within this section to install the battery into the indicator stand.1. Connect the wire connector inside the column to the battery.2. Slide the battery into the indicator stand at a slight angle and turn counterclockwise to lock it in place.Figure 2-4. Battery InstallationIMPORTANT2.5It is recommended that the battery be disconnected if the unit will not be used for 30 days or longer.Printer InstallationFor printer installation information, see the RL-HPJ Hand Pallet Jack Scale Printer Kit Installation Addendum (PN 190986).See Table 5-4 and Table 5-5 on page 42 for printer default and configuration iChee (thermal printer)9600n.8.1EnulEht.offYesTable 2-1. Required Settings Rice Lake Weighing Systems All Rights Reserved5
RL-HPJ Hand Pallet Jack Scale3.0OperationThis section describes procedures for operation of the Pallet Jack Scale.The Pallet Jack Scale is an electronic weighing system directly installed on a pallet jack.See the following information before use:3.1Pallet Jack Controls3.1.1Height Control Lever PositionsThe raised load is moved forward or backward by the handlebar, which controls the steering wheels.The height control lever has three available positions inside the upper handle: center, down or up.Center - Transport PositionThe handlebar is completely free for transport maneuvers. Allowing the pallet jack to be moved in any direction.Figure 3-1. Transport PositionDown - Lift PositionPush the height control lever to the down position. Move the handlebar down and up to lift up the forks of the pallet jack.Continue this movement until the forks are raised at least two inches off the ground to move the Pallet Jack Scale.CAUTIONA return spring pushes handlebar back to its upright position. Do not let go of handlebar until it is upright.Figure 3-2. Lift PositionUp - Lower PositionPull the height control lever to the up position to lower the load. The descent spe
The Pallet Jack Scale is ideal for handling and weighing pallets or standardized containers directly where they are located, saving time and money. The durable and precise Pallet Jack Scale is equipped with high performance weighing electronics and features a multi-functional program that helps perform daily tasks.