Transcription
FuelEquipment.comCustom fuelling solutionsSelf-Bunded Fuel Storage Tanksfor hydrocarbon liquid fuelsAustralian Fuelling Systems & Equipment manufactures a wide range of fuel storage and transporttanks. These include self-bunded and conventional tanks for diesel , ULP and aviation fuels, tanks fortransporting fuels, including demountables for diesel and tanks suitable for AS2809 compliant Dangerous Goods vehicles. We also specialise in fitting all required dispensing equipment, managementsystems and a full range of accessories to customise your tank to suit your requirements. All systemsare thoroughly wet tested prior to despatch to minimise onsite works and commissioning.Self-bundedbulk storage tanksfor diesel & ULP.Custom tanks forother fluidsavailable.Australiandesigned &manufacturedAccess ladder & platforms can beinstalled on either side of tankAustralian Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Fax: 61 2 6760 7826www.fuelequipment.comAustralianFUELLINGSystems & Equipment
FuelEquipment.comCustom fuelling solutionsGeneral InformationThe following information is provided for general guidance only on topics as shown. No responsibility is accepted for any outcomes or situations arising from your interpretation of any of theguides. In all cases it is recommended that a qualified consultant be engaged to guide your installation of fuel storage and dispensing systems.CompliancesTanks constructed by Australian FuellingSystems & Equipment are built to the following Australian StandardsAS1692- 2006 Steel tanks for flammableand combustible liquidsAS 1940-2004 The storage and handling offlammable and combustible liquidsAS1657 Fixed platforms, walkways, stairways and ladders - Design construction andinstallation.We have a rigorous QA testing regimewhich every tank undergoes prior to delivery. These include pneumatic bubble testing& full hydrotesting, depending on tank type.Aviation fuel tanksPlease be aware that tanks shown withinthis brochure are not designed for usewith aviation fuels - please see separatebrochure detailing our range.Plug & Play systemsFuel CategoriesLiquid fuels are categorised according totheir flashpoint (see AS1940)Class 3 Flammable Liquids include ULP,Avgas, Jet-A1, Mogas, most Kerosenesand a wide range of other fluids includingsolvents. These have a lower flashpointthan Diesel, which is classified as a Combustible Fluid C2.Requirements for equipment, location,electrical, site fixtures etc are more stringent for Class 3 Flammable Liquids thanfor a Combustible Liquid C2.Site & location requirementsSite requirements (foundations, footings, location, proximity to major works etc) for fueltanks are as described within AS1940-2004.Foundations & footings will need to be determined by a properly qualified person withlocal knowledge of terrain & soil types.It is highly recommended that a properlyqualified Dangerous Goods Consultant(member of the Australian Institute of Dangerous Goods Consultants) be engaged toadvise on all aspects of Class 3 FlammableLiquids storage and dispensing systems.Dispensing fuelsGetting the fuel out of your tank intovehicles, machines or other tanks requiresmuch planning and consideration of yourrequirements. Please see separate sectionwith our options packages.Basic considerations are:Flow rate requiredHose length & hose storage methodNozzle type - systems can be fitted witheither standard top fill nozzles, Wigginstype “quick-fill” nozzles or bothPump systemPower requirements to achieve flowsFlow meter - is the system to be used forreselling?FiltrationManagement system to track who, when &how much fuel was taken.Tank filling methodsIn most cases, it is beneficial for you toOur tanks are generally ready to go whencheck with your fuel supplier as to what isdelivered - except for assemly of the ladtheir preferred method of filling your tank.der/platform which is shipped separately.This can be a bottom filling system withThe ladder can be installed on either sidevarious connection fittings, top filling - weof the tank to suit.can ensure that the correct method & fitWe prefer to install any specified dispenstings are included in your tank.Transporting your tanking equipment or other accessories so that We can arrange quotation for delivery ofWe can supply your tank fitted with autowe can wet test complete operation of the your tank or you can arrange this yourself. matic shutoff at SFL (overfill protection)whole system prior to despatch.Generally, you will also need to organise & that is suitable for remote fill points.This means that onsite work is minimised co-ordinate a crane to unload & place.Warrantyto provision of suitable footings, connecPower/flowrequirementsOur tanks have a 20 year warranty fortion of required power supply and filling forAs a general guide & depending on the tank integrity when used in accordance withoperation.size accessories included, a 240v ac single standard industry practice.Tank ManagementAll equipment fitted is covered by 12phase power supply will enable a deliveryTanks can be fitted with management sys- flow rate of up to approximately 80-90 lpm. month warranty for performance as specitems that record all issues from the tank - Tanks used in industrial applications where fied and to the limits of the manufacturersvehicle id, operator id, volume, time etc.warranty.high flows are required (above 100 lpm)Tanks can be fitted with level monitoringusually will require 3 phase 415v supply or aFuel supply to Gensetsdevices accessible by phone, internet orsuitably sized engine.Please be aware that all compliant selfproprietary systems.12 & 24v DC pumps are capable of flows up bunded tanks have to be fitted with anapproximately 50 lpm.anti-siphon valve - this means that there isRetailing fuel from your tank toNote: all fluid from a compliant self-bunded no head and so the generator system mustWe can supply and fit, calibrate & certify all tank has to be delivered through an antihave adequate lift pump or be equippedrequired dispensing equipment to National siphon valve which reduces flows somewhat.with day tank and suitable refilling system.Measurement Institute standards for legalreselling of fuels if required.Enquiry? - call 1800-025 869 or email [email protected] Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Fax: 61 2 6760 7826www.fuelequipment.comAustralianFUELLINGSystems & Equipment
FuelEquipment.comCustom fuelling solutionsSelf-bunded 344050200Self-bunded cylindrical tank dimensionsABCDE3830 24122980371021006430 24122980371021006780 28623430417023509830 2862343041702350Australian Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Fax: 61 2 6760 10Mass38505750722010120FUELLINGSystems & Equipment
FuelEquipment.comCustom fuelling solutionsSelf-bunded cylindrical tanksA typical dual outlet dispensing system fitted to a self-bunded tank.Powered by 415v 3 phasesupply, this system includesdual nozzles - a standardtop fill automatic nozzle forsmaller vehicles as well asa Wiggins “quick-fill” nozzlefor rapid refuelling of heavymachinery.All deliveries are controlledand monitored by a SmartFill management systemwhich records details ofquantity, vehicle/plant id,operator, date & time. Thisdata is easily transferrableto PC to produce spreadsheets.Also fitted is a 600 lpmcentrifugal pump for highflow transfer of diesel fromdelivery tanker into storage.All equipment is safely secured in lockable enclosure.Australian Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Fax: 61 2 6760 7826www.fuelequipment.comAustralianFUELLINGSystems & Equipment
FuelEquipment.comCustom fuelling solutionsSelf-bunded cylindrical tanksA typical 240v single nozzle dispensing systemA typical 240v ac dispensingsystem - ideal for trucks, busesand other standard top-fillvehicles.Fitted with a Fill-Rite FR310series high flow pump, this system can be fitted with a varietyof options. Unit shown is fittedwith the SmartFill managementsystem to monitor all deliveries.This system delivers approximately 75-80 lpm - with variation according to the size of thetank, fuel level and the equipment included.Options available include:Various mechanical or electronic flow meters.Goldenrod 10 micron filtrationManual or spring rewind hosereel.Hose length to suit.All equipment is safely securedin lockable enclosure.Shown are various dispensing systems which can be fitted to your tank.These can include DC, 240c ac, 415v 3 phase, diesel &petrol engine-powered pumps and pneumatic systemswith single or dual outlets. Pumps can be fitted for resale,with management systems or industrial flow meters.Australian Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Fax: 61 2 6760 7826www.fuelequipment.comAustralianFUELLINGSystems & Equipment
FuelEquipment.comCustom fuelling solutionsSelf-bunded rectangular tanksFuel return connectionpoint can be fitted forgenerator fuel supplyapplicationsDieselULPCat#Cat#TypeSFL123034 123100 T1.5 1450123030 123047 T2.5 2580123032 123074 T55230Self-bunded rectangular tankABCD240011507002480241011201210 2490320011201810 All dimensions shown are nominal and can vary due to manufacturing and plate dimension variationsSafe Fill Level is 97% of gross volumeTanks for ULP supplied with vent risers to 4m from ground level - to be fitted on siteWe normally supply all self-adhesive signage for Class 3 product tanks to be fitted onsite due to transport regulations.Various dispensing systems for rectangular self-bunded tanksAustralian Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Fax: 61 2 6760 7826www.fuelequipment.comAustralianFUELLINGSystems & Equipment
FuelEquipment.comCustom fuelling solutionsSelf-bunded rectangular tanksAustralian designed& manufacturedA 5000 litre self-bunded tank for ULP. Supplied withpiping to connect to bowser at service station site.Australian Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Fax: 61 2 6760 7826www.fuelequipment.comAustralianFUELLINGSystems & Equipment
FuelEquipment.comCustom fuelling solutionsSelf-Bunded Waste oil Tanks5000 litre self-bunded tank custom made for waste oil collection in a busy workshop. Features collection funnel, overfill warning alarm, interstitial monitoring, spill containment and step for safe access.Other tanks in our rangeTanks To AS2809 for DG vehiclesDiesel tanks for service trucksSelf-bunded aviation fuel tanksDemountable self-bunded tanks Oil & water tanks for service trucks Aluminium tanks to AS2809Got a question?Need a quote?Tanks to AS2809 for trailersCall 1800-025 869 oremail [email protected] Fuelling Systems & EquipmentPO Box 7162 NEMSC 2348 7-11 Armstrong Street Tamworth 2340Ph: 61 2 6760 7816Aviation fuel tanksFax: 61 2 6760 7826www.fuelequipment.comAustralianFUELLINGSystems & Equipment
either standard top fill nozzles, Wiggins type “quick-fill” nozzles or both Pump system Power requirements to achieve flows Flow meter - is the system to be used for reselling? Filtration Management system to track who, when & how much fuel was taken. In most cases, it is beneficial for you to che