SERVICE MANUALSERVICE MANUAL SECTIONBODY CONTROLLER DIAGNOSTIC TROUBLE CODESModel: 3200Model: 4100Model: 4300Model: 4400Model: 7300Model: 7400Model: 7500Model: 7600Model: 7700Model: 8500Model: 8600Model: BE 200Model: CE BusModel: CXTModel: DuraStarModel: LoneStarModel: MXTModel: ProStarS08327Copyright 08/16/2010 Navistar, Inc.

Model: RXTModel: TranStarModel: WorkStarS0832708/16/2010S08327Copyright 08/16/2010 Navistar, Inc.

TABLE OF CONTENTSTABLE OF CONTENTS1. DISPLAYING DIAGNOSTIC TROUBLE CODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1. VEHICLES EQUIPPED WITH OPTION TO DISPLAY CODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.1.1. Displaying Codes on the Gauge Cluster (Non-VID equipped vehicles). . . . . . . . . . . . . . . . . . . . . . . . .1.1.2. Displaying Codes on the VID (if equipped). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11122. CLEARING DIAGNOSTIC TROUBLE CODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23. DEFINITIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.1. FAILURE MODE INDICATORS (FMI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33.2. SOURCE ADDRESSES (SA). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44. DIAGNOSTIC TROUBLE CODE (DTC) LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4BODY CONTROLLER DIAGNOSTIC TROUBLE CODES (S08327)i

iiBODY CONTROLLER DIAGNOSTIC TROUBLE CODESS08327

DISPLAYING DIAGNOSTIC TROUBLE CODES1. DISPLAYING DIAGNOSTIC TROUBLE CODESThe ability to display diagnostic trouble codes (DTC) is an optional feature. Codes may be displayed on eitherthe gauge cluster or an optional vehicle information display (VID). The vehicle must be equipped with theoption to display codes in both cases. Codes will not be displayed on the gauge cluster if the vehicle isequipped with the VID.1.1. VEHICLES EQUIPPED WITH OPTION TO DISPLAY CODES1.1.1. Displaying Codes on the Gauge Cluster (Non-VID equipped vehicles)To display codes on vehicles not equipped with a VID:1. Set the parking brake.2. Turn the key switch to the ACCESSORY position to view only previously active codes. Turn the key switchto the IGNITION position to view both active and previously active codes.3. Momentarily press the Cruise "ON" switch and the Cruise "Resume" switch at the same time.A gauge sweep will be performed on the gauges. The gauge cluster will then display the following informationfor 5 seconds: Software Rev: XXX Hardware Rev: XXX Active Faults: XXX Total Faults: XXXNOTE – The gauge cluster will only display “Software Rev” and “Hardware Rev” for 5 seconds followedby the message “Diagnostic Trouble Codes are not available” if the vehicle is not equipped with theoption to display codes.If faults are present, the gauge cluster display will show each diagnostic trouble code for 10 seconds andthen automatically scroll to the next entry and continue to cycle through the faults. Once all faults havebeen displayed the number of faults will be displayed again, then the cycle will repeat. To manually cyclethrough the fault list press and release the cluster display selector button. The following information will bedisplayed for each fault:SPN: XXXX FMI: XXActiveOC: XXX SA: XXXSPN: XXXX FMI: XXPreviously ActiveOC: XXX SA: XXXNOTE – Turning the key switch off, turning the key switch to the CRANK position, or releasing the parkbrake will take the gauge cluster out of the diagnostic mode.BODY CONTROLLER DIAGNOSTIC TROUBLE CODES (S08327)1

DEFINITIONS1.1.2. Displaying Codes on the VID (if equipped)The VID can be used to display all diagnostic trouble codes (DTC) on the vehicle. Suspect parameter number(SPN), failure mode indicator (FMI) and occurrence count numbers are listed. Source addresses and DTCdescriptions are presented in plain text.NOTE – The VID will display “Not Available” if a DTC description is not available for a particular fault.Displaying codes will only be allowed if all of the following conditions are true: The key switch is in the IGNITION position. AND displaying codes is allowed due to vehicle orderable options AND the programmable parameter “Diagnostics” is enabled using Diamond Logic Builder (DLB). The vehicle is not moving (the Vehicle Speed is equal to zero). The feature is not password protected to prevent unauthorized access. Refer to the Vehicle InformationDisplay Owner’s Manual for more information.Perform the following steps if all of the above conditions are met:1. Go to the main menu screenNOTE – The following selections will not be available if the vehicle is not equipped with the option todisplay codes.2. Select “DIAGNOSTIC CODES”3. Select “ACTIVE” or “INACTIVE”. The VID may initiate a password prompt if the VID has been passwordprotected. Refer to the Vehicle Information Display Owner’s Manual for more information.The VID will indicate "NO FAULT DETECTED" if faults are not found. Scroll through the list of faults if faultsare present.The following information will be displayed for each fault:SPN : FMISADTC DescriptionOC2. CLEARING DIAGNOSTIC TROUBLE CODESPreviously active diagnostic trouble codes can only be cleared by a service tool, such as Diamond Logic Builder (DLB). Some previously active codes may not be cleared by this method.3. DEFINITIONS “SPN” represents the Suspect Parameter Number. This number identifies the item for which diagnosticsare being reported. “FMI” is the Failure Mode Indicator. This number represents the type of failure detected. Refer to FailureMode Indicators (FMI) below for more information.2BODY CONTROLLER DIAGNOSTIC TROUBLE CODES (S08327)

FAILURE MODE INDICATORS (FMI)DEFINITIONS “Active” or “Previously Active” will be displayed to identify whether a fault is currently active or if the faultwas previously active. “OC” is the Occurrence Count. This number represents the number of times a fault has gone frompreviously active to active. “SA” is the Source Address. This number identifies the module reporting the fault. Refer to SourceAddresses (SA) for more information.3.1. FAILURE MODE INDICATORS (FMI) FMI 0 - Data Valid But Above Normal Operational Range - Most Severe Level FMI 1 - Data Valid But Below Normal Operational Range - Most Severe Level FMI 2 - Data Erratic, Intermittent Or Incorrect FMI 3 - Voltage Above Normal, Or Shorted To High Source FMI 4 - Voltage Below Normal, Or Shorted To Low Source FMI 5 - Current Below Normal Or Open Circuit FMI 6 - Current Above Normal Or Grounded Circuit FMI 7 - Mechanical System Not Responding Or Out Of Adjustment FMI 8 - Abnormal Frequency Or Pulse Width Or Period FMI 9 - Abnormal Update Rate FMI 10 - Abnormal Rate Of Change FMI 11 - Root Cause Not Known FMI 12 - Bad Intelligent Device Or Component FMI 13 - Out Of Calibration FMI 14 - Special Instructions FMI 15 - Data Valid But Above Normal Operating Range - Least Severe Level FMI 16 - Data Valid But Above Normal Operating Range - Moderately Severe Level FMI 17 - Data Valid But Below Normal Operating Range - Least Severe Level FMI 18 - Data Valid But Below Normal Operating Range - Moderately Severe Level FMI 19 - Received Network Data In Error FMI 20 - Data Drifted High FMI 21 - Data Drifted Low FMI 31 - Condition ExistsBODY CONTROLLER DIAGNOSTIC TROUBLE CODES (S08327)3

DEFINITIONSSOURCE ADDRESSES (SA)3.2. SOURCE ADDRESSES (SA)NOTE – The available source addresses will vary depending on each vehicle configuration.NOTE – Diagnostic Trouble Codes listed in this document are Body Controller, Auxiliary Gauge SwitchPack, Secondary Instrument Cluster, Instrument Cluster, Rear HVAC Module, and Compass Module.Module NameSource AddressEngine Control Module (ECM)00Transmission Control Module (TCM)03Shift Selector05Antilock Brake System (ABS)11Electronic Gauge Cluster (EGC)23Compass Module28Body Controller33Vehicle Sensor Module (VSM)39Vehicle Information Display (VID)40Tire Pressure Monitoring System (TPMS)51Rear HVAC58Aftertreatment Module61Telematics Module74Auxiliary Gauge Switch Pack (AGSP) 3132Secondary Instrument Cluster (SIC) 1167Hybrid Electric Vehicle (HEV) or Eaton Transmission Control Pad239Power Pack 3247Service Tool249Global2554. DIAGNOSTIC TROUBLE CODE (DTC) LIST4BODY CONTROLLER DIAGNOSTIC TROUBLE CODES (S08327)

SASPNDTC DescriptionFMI MessageFault on AnalogInput 3 abovenormal when usedfor outsidetemperatureFault on AnalogInput 3 belownormal when usedfor outsidetemperatureCauseVoltage above normal,or shorted to highsource171Ambient AirTemperature23171Ambient AirTemperature423623Red Stop Lamp5Red stop lightmalfunctionCurrent below normalor open circuit23624Amber WarningLamp5Amber Warninglight malfunctionCurrent below normalor open circuit233Voltage below normal,or shorted to lowsource23928Axle Location3Fault on AnalogVoltage above normal,Input 1 when used or shorted to highfor axle loadsource23928Axle Location4Voltage below normal,Fault on AnalogInput 1 when used or shorted to lowsourcefor axle load23987Protect Lamp5Protect warninglight malfunctionCurrent below normalor open circuit231213MalfunctionIndicator Lamp5MIL warning lightmalfunctionCurrent below normalor open circuitCommentsPinsLogical Signal

SASPNDTC DescriptionFMI Message1438ABS/EBS AmberWarning LampState (PoweredVehicle)5231439EBS Red WarningLamp State5231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)1423231705Gauge Cluster (v8.7)14ABS warning lightmalfunctionBrake Pressurewarning lampmalfunctionGauge Cluster(address 23), lostcommunicationwith ESC.Gauge Cluster(address 23), lostcommunicationwith enginecontroller.Gauge Cluster(address 23). ABSwarning lightmalfunction.Gauge Cluster(address 23).Trailer ABS (Bus LiftGate) warning lightmalfunction.CauseCommentsCurrent below normalor open circuitCurrent below normalor open circuitLoss of drive‐train data Loss of communication inlink.excess of 10 seconds.Loss of drive‐train data Loss of communication inlink.excess of 10 seconds.PinsLogical Signal

SA232323SPNDTC Description1705Gauge Cluster (v8.7)1705Gauge Cluster (v8.7)1705Gauge Cluster (v8.7)FMI MessageComments14Gauge Cluster(address 23).Datalink ignitionsignal does notmatch thehardwired ignitionsignal.14Gauge Cluster(address 23) gaugelocation 1, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 1, data outof range low.Data for this gauge is belowthe value that can bedisplayed.1705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)1423Cause14Gauge Cluster(address 23) gaugelocation 1, sensorfault.Gauge Cluster(address 23) gaugelocation 1, dataunavailable.Gauge Cluster(address 23) gaugelocation 1, datamissing.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.PinsLogical Signal

SA23SPN1705DTC DescriptionGauge Cluster (v8.7)FMI Message14Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 2, data outof range low.Data for this gauge is belowthe value that can bedisplayed.17051705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)1423232317051705Gauge Cluster (v8.7)Gauge Cluster (v8.7)CommentsGauge Cluster(address 23) gaugelocation 2, data outof range high.Gauge Cluster (v8.7)23CauseGauge Cluster(address 23) gaugelocation 2, sensorfault.Gauge Cluster(address 23) gaugelocation 2, dataunavailable.Gauge Cluster(address 23) gaugelocation 2, datamissing.The data for this gaugeshould be, but is notavailable.14Gauge Cluster(address 23) gaugelocation 3, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 3, data outof range low.Data for this gauge is belowthe value that can bedisplayed.14There is a problem with thesensor that provides data forthis gauge.The data for this gauge isnot being transmitted.PinsLogical Signal

SASPNDTC DescriptionFMI Message231705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)141705Gauge Cluster (v8.7)23231705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14Gauge Cluster(address 23) gaugelocation 3, sensorfault.Gauge Cluster(address 23) gaugelocation 3, dataunavailable.Gauge Cluster(address 23) gaugelocation 3, datamissing.CauseCommentsThere is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 4, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 4, data outof range low.Data for this gauge is belowthe value that can bedisplayed.1414Gauge Cluster(address 23) gaugelocation 4, sensorfault.Gauge Cluster(address 23) gaugelocation 4, dataunavailable.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.PinsLogical Signal

SA232323SPNDTC Description1705Gauge Cluster (v8.7)1705Gauge Cluster (v8.7)1705Gauge Cluster (v8.7)FMI MessageComments14Gauge Cluster(address 23) gaugelocation 4, datamissing.The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 5, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 5, data outof range low.Data for this gauge is belowthe value that can bedisplayed.231705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)141705Gauge Cluster (v8.7)23Cause1414Gauge Cluster(address 23) gaugelocation 5, sensorfault.Gauge Cluster(address 23) gaugelocation 5, dataunavailable.Gauge Cluster(address 23) gaugelocation 5, datamissing.The data for this gaugeshould be, but is notavailable.Gauge Cluster(address 23) gaugelocation 6, data outof range high.Data for this gauge is abovethe value that can bedisplayed.There is a problem with thesensor that provides data forthis gauge.The data for this gauge isnot being transmitted.PinsLogical Signal

SASPNDTC DescriptionFMI Message1705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)1423232323170517051705Gauge Cluster (v8.7)Gauge Cluster (v8.7)Gauge Cluster (v8.7)14Gauge Cluster(address 23) gaugelocation 6, data outof range low.Gauge Cluster(address 23) gaugelocation 6, sensorfault.Gauge Cluster(address 23) gaugelocation 6, dataunavailable.Gauge Cluster(address 23) gaugelocation 6, datamissing.CauseCommentsData for this gauge is belowthe value that can bedisplayed.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 7, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 7, data outof range low.Data for this gauge is belowthe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 7, sensorfault.There is a problem with thesensor that provides data forthis gauge.PinsLogical Signal

SASPNDTC Description231705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)FMI Message1414The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.14Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 8, data outof range low.Data for this gauge is belowthe value that can bedisplayed.17051705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)1423CommentsGauge Cluster(address 23) gaugelocation 8, data outof range high.Gauge Cluster (v8.7)23Gauge Cluster(address 23) gaugelocation 7, dataunavailable.Gauge Cluster(address 23) gaugelocation 7, datamissing.Cause14Gauge Cluster(address 23) gaugelocation 8, sensorfault.Gauge Cluster(address 23) gaugelocation 8, dataunavailable.Gauge Cluster(address 23) gaugelocation 8, datamissing.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.PinsLogical Signal

SA23SPN1705DTC DescriptionGauge Cluster (v8.7)FMI Message14Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 9, data outof range low.Data for this gauge is belowthe value that can bedisplayed.17051705Gauge Cluster (v8.7)231705Gauge Cluster (v8.7)14231705Gauge Cluster (v8.7)1423232317051705Gauge Cluster (v8.7)Gauge Cluster (v8.7)CommentsGauge Cluster(address 23) gaugelocation 9, data outof range high.Gauge Cluster (v8.7)23CauseGauge Cluster(address 23) gaugelocation 9, sensorfault.Gauge Cluster(address 23) gaugelocation 9, dataunavailable.Gauge Cluster(address 23) gaugelocation 9, datamissing.The data for this gaugeshould be, but is notavailable.14Gauge Cluster(address 23) gaugelocation 10, dataout of range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 10, dataout of range low.Data for this gauge is belowthe value that can bedisplayed.14There is a problem with thesensor that provides data forthis gauge.The data for this gauge isnot being transmitted.PinsLogical Signal

SA232323232323SPNDTC Description1705Gauge Cluster (v8.7)1705Gauge Cluster (v8.7)1705Gauge Cluster (v8.7)1725Front Axle AbovePressure1725Front Axle BelowPressure1727Rear Axle AbovePressureFMI MessageCauseComments14Gauge Cluster(address 23) gaugelocation 10, sensorfault.There is a problem with thesensor that provides data forthis gauge.14Gauge Cluster(address 23) gaugelocation 10, dataunavailable.The data for this gaugeshould be, but is notavailable.14Gauge Cluster(address 23) gaugelocation 10, datamissing.The data for this gauge isnot being transmitted.3Fault on AnalogVoltage above normal,Input 2 aboveor shorted to highnormal when usedsourcefor axle load4Fault on AnalogVoltage below normal,Input 2 belowor shorted to lownormal when usedsourcefor axle load3Fault on AnalogVoltage above normal,Input 1 aboveor shorted to highnormal when usedsourcefor axle loadPinsLogical Signal

SASPNDTC DescriptionFMI MessageCause231727Rear Axle BelowPressure4Fault on AnalogVoltage below normal,Input 1 belowor shorted to lownormal when usedsourcefor axle load231792Tractor‐MountedTrailer ABSWarning Signal5Trailer ABS warning Current below normallight malfunction or open circuit231793ATC/ASR5Information Signal232000Source Address 09232003Source Address 39232011Source Address 11 9232023Gauge Cluster14232023Gauge Cluster14Traction Controlwarning lightmalfunctionLoss of data linkfrom EngineControllerLoss of data linkfrom theTransmissionControllerLoss of data linkfrom ABScontrollerGauge Cluster(address 23), lostcommunicationwith ESC.Gauge Cluster(address 23), lostcommunicationwith enginecontroller.CommentsCurrent below normalor open circuitAbnormal update rateAbnormal update rateAbnormal update rateLoss of drive‐train data Loss of communication inlink.excess of 10 seconds.Loss of drive‐train data Loss of communication inlink.excess of 10 seconds.PinsLogical Signal

SA232323232323SPN202320232023202320232023DTC DescriptionGauge ClusterGauge ClusterGauge ClusterGauge ClusterGauge ClusterGauge ClusterFMI MessageCauseComments14Gauge Cluster(address 23). ABSwarning lightmalfunction.14Gauge Cluster(address 23).Trailer ABS (Bus LiftGate) warning lightmalfunction.14Gauge Cluster(address 23).Datalink ignitionsignal does notmatch thehardwired ignitionsignal.14Gauge Cluster(address 23) gaugelocation 1, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 1, data outof range low.Data for this gauge is belowthe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 1, sensorfault.There is a problem with thesensor that provides data forthis gauge.PinsLogical Signal

SASPNDTC DescriptionFMI Message232023Gauge Cluster14232023Gauge Cluster14232323202320232023Gauge ClusterGauge ClusterGauge ClusterGauge Cluster(address 23) gaugelocation 1, dataunavailable.Gauge Cluster(address 23) gaugelocation 1, datamissing.CauseCommentsThe data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 2, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 2, data outof range low.Data for this gauge is belowthe value that can bedisplayed.14232023Gauge Cluster14232023Gauge Cluster14Gauge Cluster(address 23) gaugelocation 2, sensorfault.Gauge Cluster(address 23) gaugelocation 2, dataunavailable.Gauge Cluster(address 23) gaugelocation 2, datamissing.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.PinsLogical Signal

SA232323SPN202320232023DTC DescriptionGauge ClusterGauge ClusterGauge ClusterFMI Message14Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 3, data outof range low.Data for this gauge is belowthe value that can bedisplayed.142023Gauge Cluster14232023Gauge Cluster142320232023Gauge ClusterGauge ClusterCommentsGauge Cluster(address 23) gaugelocation 3, data outof range high.2323CauseGauge Cluster(address 23) gaugelocation 3, sensorfault.Gauge Cluster(address 23) gaugelocation 3, dataunavailable.Gauge Cluster(address 23) gaugelocation 3, datamissing.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 4, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 4, data outof range low.Data for this gauge is belowthe value that can bedisplayed.PinsLogical Signal

SASPNDTC DescriptionFMI Message232023Gauge Cluster14232023Gauge Cluster14232023Gauge Cluster14232320232023Gauge ClusterGauge ClusterGauge Cluster(address 23) gaugelocation 4, sensorfault.Gauge Cluster(address 23) gaugelocation 4, dataunavailable.Gauge Cluster(address 23) gaugelocation 4, datamissing.CauseCommentsThere is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 5, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 5, data outof range low.Data for this gauge is belowthe value that can bedisplayed.232023Gauge Cluster14232023Gauge Cluster14Gauge Cluster(address 23) gaugelocation 5, sensorfault.Gauge Cluster(address 23) gaugelocation 5, dataunavailable.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.PinsLogical Signal

SA232323SPN202320232023DTC DescriptionGauge ClusterGauge ClusterGauge ClusterFMI Message14The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 6, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 6, data outof range low.Data for this gauge is belowthe value that can bedisplayed.2023Gauge Cluster14232023Gauge Cluster14232023Gauge Cluster142023Gauge ClusterCommentsGauge Cluster(address 23) gaugelocation 5, datamissing.2323Cause14Gauge Cluster(address 23) gaugelocation 6, sensorfault.Gauge Cluster(address 23) gaugelocation 6, dataunavailable.Gauge Cluster(address 23) gaugelocation 6, datamissing.The data for this gaugeshould be, but is notavailable.Gauge Cluster(address 23) gaugelocation 7, data outof range high.Data for this gauge is abovethe value that can bedisplayed.There is a problem with thesensor that provides data forthis gauge.The data for this gauge isnot being transmitted.PinsLogical Signal

SA23SPN2023DTC DescriptionGauge ClusterFMI Message1414Gauge Cluster(address 23) gaugelocation 8, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 8, data outof range low.Data for this gauge is belowthe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 8, sensorfault.There is a problem with thesensor that provides data forthis gauge.Gauge Cluster14232023Gauge Cluster14232023Gauge Cluster14232320232023Gauge ClusterGauge ClusterGauge ClusterData for this gauge is belowthe value that can bedisplayed.The data for this gaugeshould be, but is notavailable.20232023CommentsGauge Cluster(address 23) gaugelocation 7, sensorfault.Gauge Cluster(address 23) gaugelocation 7, dataunavailable.Gauge Cluster(address 23) gaugelocation 7, datamissing.2323Gauge Cluster(address 23) gaugelocation 7, data outof range low.CauseThere is a problem with thesensor that provides data forthis gauge.The data for this gauge isnot being transmitted.PinsLogical Signal

SASPNDTC DescriptionFMI Message232023Gauge Cluster14232023Gauge Cluster14232323202320232023Gauge ClusterGauge ClusterGauge ClusterGauge Cluster(address 23) gaugelocation 8, dataunavailable.Gauge Cluster(address 23) gaugelocation 8, datamissing.CauseCommentsThe data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.14Gauge Cluster(address 23) gaugelocation 9, data outof range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 9, data outof range low.Data for this gauge is belowthe value that can bedisplayed.14232023Gauge Cluster14232023Gauge Cluster14Gauge Cluster(address 23) gaugelocation 9, sensorfault.Gauge Cluster(address 23) gaugelocation 9, dataunavailable.Gauge Cluster(address 23) gaugelocation 9, datamissing.There is a problem with thesensor that provides data forthis gauge.The data for this gaugeshould be, but is notavailable.The data for this gauge isnot being transmitted.PinsLogical Signal

SA23232323232323SPN2023202320232023202320232023DTC DescriptionGauge ClusterGauge ClusterGauge ClusterGauge ClusterGauge ClusterGauge ClusterGauge ClusterFMI MessageCauseComments14Gauge Cluster(address 23) gaugelocation 10, dataout of range high.Data for this gauge is abovethe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 10, dataout of range low.Data for this gauge is belowthe value that can bedisplayed.14Gauge Cluster(address 23) gaugelocation 10, sensorfault.There is a problem with thesensor that provides data forthis gauge.14Gauge Cluster(address 23) gaugelocation 10, dataunavailable.The data for this gaugeshould be, but is notavailable.14Gauge Cluster(address 23) gaugelocation 10, datamissing.The data for this gauge isnot being transmitted.3Fault on AnalogVoltage above normal,Input 4 aboveor shorted to highnormal when usedsourcefor ambient light4Fault on AnalogInput 4 belowwhen used forambient lightVoltage below normal,or shorted to lowsourcePinsLogical Signal

SASPNDTC DescriptionFMI MessageCause232023Gauge Cluster11Message ignitionand switchedignition do notmatch.232023Gauge Cluster12Failure of non‐Bad intelligent devicevolatile memory oror componentchecksum fault232023Gauge Cluster6Short detected inthe panel dimmer232033Source Address 33 9232062Source Address 62 928165Compass Bearing1228630CalibrationMemory1328639Drivetrain Message2TimeoutLoss of data linkfrom ESCLoss of data linkfrom MeritorWabco BrakeController to EGCSensor Fault/Compass BearingCompass is out ofCalibrationRoot cause not knownCurrent above normalor grounded circuitAbnormal update rateMeritor Wabco BrakeController data linkfailure to EGCFaulty Compass modulesensorCompass is out ofcalibration, need toCalibrateEEPROM data inthe MicrocontrollerData erratic,is corrupted orError in Calibration intermittent orincorrect(The Compassmodule is notcalibrated.)CommentsPinsLogical Signal

SASPNDTC DescriptionFMI MessageCauseComments639Drivetrain Message19TimeoutHMC6352 sensor isnot responding orcommunicationFaulty Compass modulelink with HMC6352or I2C communication(I2Clinkcommunicationlink) not workingreliably.28639Drivetrain Message9TimeoutJ1939CommunicationLink FaultFaulty Compass orDrivetrain Datalink3369Two Speed AxleSwitch2Two Speed AxleSwitch ErrorData erratic, intermittentor incorrect2Occurs When the Park BrakeSwitch is not set within 5The Auto applyseconds of the receipt of theportion with the AirPark as the requested gear.Data erratic, intermittentPowered ParkThis failure would indicate aor incorrectBrake is notfailure in the auto apply relayOperatingor in the air lines between theauto apply relay and the ParkBrake switch.7Occurs when the park brakeswitch does not match thespring apply-air release(SAAR) chamber travelsensor. This indicates thepark brake cannot be appliedor cannot be released.2833337070Air Powered ParkBrakeAir Powered ParkBrakeAir Powered ParkBrake is stuckMechanical system notresponding or out ofadjustmentPinsLogical SignalTwo Spd Axle Switch

SA333333333333SPN7070DTC DescriptionAir Powered ParkBrakeAir Powered ParkBrakeFMI Messa