DETECTIONPERSONAL PROTECTIONDIVING TECHNOLOGYSYSTEM TECHNOLOGYSERVICESST-2507-2005Dräger Pac 7000ST-1758-2005Small and robust, ergonomic and intuitive, economic and powerful – the Dräger Pac7000 is tailor-made for personal monitoring at the workplace. This innovative singlegas detector is equipped with a wide range of functions and is suitable for manydifferent applications in day-to-day industrial settings. The detector is an impressiveinstrument, offering a high level of reliability and rapid warning against harmfulconcentrations of CO, CO2, Cl2, HCN, H2S, NH3, NO2, O2, PH3, SO2.Dräger Pac 7000:High performance andunlimited use.uously, as are notice and warning functions. In addition, the respective peak concentration, average concentration (TWAvalue) and short-term exposure limit(STEL) relating to the measurement periodcan be accessed.Concentration displayThe concentration display uses no writtentext (to avoid language problems), showingall information in the form of large numerals or symbols. In case of an alarm, or atthe push of a button, the display can bebacklit for better readability. The currentlymeasured concentration is displayed contin-Alarm / warning functionsIn conjunction with a vibration alarm, avisual and audible alarm is triggered if thetwo adjustable alarm thresholds are exceeded (or if oxygen levels fall below the setvalue). For optimum perception a two-tonealarm is used. Furthermore, Dräger Pac7000 features an adjustable TWA alarmST-5598-2003Small and robustWith its compact, handy, pocket-sizeddesign, Dräger Pac 7000 is tailor-made forpersonal monitoring in daily work activities.Dräger Pac 7000 was specially designedas a small and robust instrument to meetwork requirements. The impact-resistanthousing features a protective rubber coating and is resistant to corrosive chemicals.Dräger Pac 7000 meets the requirementsof IP 65. What is more, protection againstelectromagnetic effects was specially optimized, while a stable and tightly lockingcrocodile clip made of stainless steelallows the instrument to be fastened securely to the wearer's clothing. To allow forindividual preferences, the crocodile clipcan be turned and the two alarm lights arepositioned diagonally opposite at the corners of the instrument. Easy battery andsensor replacement are key factors toensure a long instrument life.New sensor technology "en miniature"Dräger Pac 7000 boasts the latest in sensor technology. The small size of the sensor supports the application-orienteddesign of the instrument. Any gas hazardsthat may occur are displayed immediatelythanks to the very short diffusion pathsinside the instrument and the extremelyquick electrochemical reaction timesachieved by the new sensors. The sensoris positioned inside the housing such as toallow gas to reach it from above and fromin front. This positioning minimizes thedanger of the gas inlet opening being accidentally covered.
Dräger Pac 7000and STEL alarm. A warning is likewisegiven at the end of the battery capacity orin the event of a device error.Bump test modeThe safety of personnel must always havethe first priority. Their safety depends onmeasurement and warning equipment functioning perfectly, which is why nationalregulations demand regular testing ofequipment function using a known gasconcentration. Dräger Pac 7000 is equipped with a bump test mode. When a bumptest (function test or challenge test) needsto be performed, a notice icon appears onthe screen. The bump test interval can beset by the user.The result of the bump test is saved in theThe instrument is equipped with an IRinterface and can be linked to a PC via theconnecting cradle or E-Cal system. DrägerPac Vision or Dräger CC Vision softwareinstalled on the PC enables configurationof all functions, as well as calibration anddownload of the stored data.Adjustable operating timeIn addition, the instrument allows an individual operating time to be set (in days), e.g.a calibration interval, inspection interval orindividual operating time end.Data loggerDräger Pac 7000 features a data logger inwhich all concentrations and events arestored together with their respective datesDrägerSensorsNew XXS sensors reactparticularly quicklyLarge displayClearly structured, scratch-proof displayshowing all information at a glanceST-1758-2005Robust housingImpact-resistance andergonomic designinstrument's memory. Dräger Bump TestStation is available for easy performance ofthe bump test.Calibration and configurationDräger Pac 7000 features a menu fromwhich the bump test mode, fresh air calibration and span calibration can be selected. Access to fresh air and span calibration can be password-protected.and times. The intervals at which peakconcentrations are saved are variable andcan be adjusted by the user. If a one-minute interval is set, the data logger has acapacity of about five days. The storeddata can be downloaded via a PC and theinstalled Dräger Pac Vision or Dräger CCVision software and edited using, for example, Microsoft EXCEL software orDräger GasVision software.
Dräger Pac 7000 at a glanceGas inflow from top and frontUnlimited instrument lifeEasy sensor replacementNo-text display (no language problems)Continuous concentration displayVisual alarmAudible alarmVibration alarmTwo adjustable alarm thresholdsAdjustable TWA alarmAdjustable STEL alarmDisplay of peak concentrationBattery pre- and main alarm- Adjustable operating time with preand main alarm- Adjustable bump test interval- Adjustable bump test mode- Password-protected menu for fresh airand sensitivity calibration- IR interface- Individual instrument configuration- Replaceable battery- Data loggerFor further information, please visit:www.draeger-safety.com/pacST-5826-2004-O R D E R I N FO R M AT I O NMeasuringAlarmsAlarmsThreshold A 1Threshold A 2Order-codeDräger Pac 7000 CO1)0 to 1999 ppm30 ppm60 ppm83 18 673Dräger Pac 7000 CO2)0 to 1999 ppm35 ppm50 ppm83 18 970Dräger Pac 7000 CO0 to 1999 ppmby customer request1)0 to 100 ppm10 ppm20 ppm83 18 674Dräger Pac 7000 H2S2)0 to 100 ppm10 ppm20 ppm83 18 971Dräger Pac 7000 H2S0 to 100 ppmby customer requestDräger Pac 7000 O21)0 to 25 Vol.-%19 Vol.-%23 Vol.-%83 18 675Dräger Pac 7000 O22)0 to 25 Vol.-%19.5 Vol.-%23.5 Vol.-%83 18 972Dräger Pac 7000 O20 to 25 Vol.-%by customer requestDräger Pac 7000 CO20 to 5 Vol.-%0.5 Vol.-%3 Vol.-%83 18 975Dräger Pac 7000 CI20 to 20ppm0.5 ppm183 18 978Dräger Pac 7000 HCN0 to 50ppm10 ppm20 ppm83 18 973Dräger Pac 7000 NH30 to 300 ppm50 ppm100 ppm83 18 979Dräger Pac 7000 NO20 to 50ppm5ppm10 ppm83 18 977Dräger Pac 7000 PH30 to 20ppm0.1 ppm0.2 ppm83 18 974Dräger Pac 7000 SO20 to 100 ppm1283 18 976Dräger Pac 7000 H2S1)2)ppm83 18 67683 18 67783 18 678ppmppmDefault configuration EuropeDefault configuration NAFTAAC C E S S O R I E SConnecting Cradle, complete with USB cable and Dräger Pac Vision software83 18 587Lithium battery45 43 808Dust and water filter45 43 836Leather carrying case45 43 822Dräger Bump Test Station, complete with test gas cylinder 58 L83 18 586(gas type by customer request)E-Cal instrument module for connection of4 Dräger Pac 1000 to 7000 to a Dräger E-Cal Master Station or to Module Adapter83 18 589ST-5827-2004DescriptionDräger Pac 7000:Reliable in daily use.Dräger Pac 7000:High level of wearing comfort.
T EC H N I C A L DATADimensions (H x W x D)64 x 84 x 20 (battery compartment: 25) mm (2.5 x 3.3 x 0.8 in., battery compartment: 1 in.)Weight120 g (3.8 oz.)Ambient conditionsTemperature1)-30 to 50 C (-20 to 120 F)Pressure700 to 1300 hPaHumidity10 to 90 % r. h.Ingress protectionIP 65Language-free LCD display, continuous indication of concentration, indication of concentrationduring alarm, peak concentration, TWA- and STEL-concentration, operating time, notice andwarning functionsTypical battery life3 years (O2 sensor 1.5 years)Acoustic alarmTwo-tone-alarm, typical 90 dB (A) at a distance of 30 cmData loggerStorage of concentration und events with date and timeApprovalsCE-Sign (89/336/EEC, 94/9/EC)ATEXII 1 G EEx ia IIC, T4I M 1 EEx ia I, T 41)ULClass I, II, Div 1, Group A, B, C, D, E, F, G, Temp. Code T4cULClass I, II, Div 1, Group A, B, C, D, E, F, G, Temp. Code T4IECExEEx ia IIC, T4Dräger Pac 7000 CO2 -20 to 40 C (-4 to 104 F)Dräger Pac 7000 HCN -20 to 50 C (-4 to 122 F)Dräger Pac 7000 PH3 -20 to 50 C (-4 to 122 F)SUBSIDIARIESAUSTRALIAFRANCESINGAPOREUNITED KINGDOMDraeger Safety Pacific Pty. Ltd.Axxess Corporate ParkMt. Waverley. Vic 3149Tel 61 3 92 65 50 00Fax 61 3 92 65 50 95Dräger Safety France S.A.S.3c, Route de la Fédération67025 Strasbourg CedexTel 33 388 40 76 76Fax 33 388 40 76 67Draeger Safety Asia Pte. Ltd.67 Ayer Rajah Crescent # 06 03139950 SingaporeTel 65 68 72 92 88Fax 65 67 73 20 33Draeger Safety UK Ltd.Kitty Brewster Industrial EstateBlyth, Northumberland NE24 4RGTel 44 1670 352 891Fax 44 1670 356 266CANADAMEXICOREP. OF SOUTH AFRICAUSADraeger Canada Ltd.7555 Danbro CrescentMississauga, Ontario L5N 6P9Tel 1 905 821 8988Fax 1 905 821 2565Draeger Safety S.A. de C.V.Av. Peñuelas No. 5Querétaro, Qro MéxicoTel 52 442 246 1113Fax 52 442 246 1114Dräger South Africa (Pty) Ltd.P.O.Box 68601Bryanston 2021Tel 27 11 465 99 59Fax 27 11 465 69 53Draeger Safety, Inc.101 Technology DrivePittsburgh, PA 15275Tel 1 412 787 8383Fax 1 412 787 2207P. R. CHINANETHERLANDSSPAINBeijing Fortune DraegerSafety Equipment Co., Ltd.Beijing 101300Tel 86 10 80 49 80 00Fax 86 10 80 49 80 05Dräger Safety Nederland B.V.Edisonstraat 532700 AH ZoetermeerTel 31 79 344 46 66Fax 31 79 344 47 90Draeger Safety Hispania S.A.Calle Xaudaró 528034 MadridTel 34 91 728 34 00Fax 34 91 729 48 99Dräger Safety AG & Co. KGaARevalstrasse 123560 Luebeck, GermanyTel 49 451 882 0Fax 49 451 882 2080www.draeger-safety.com90 46 061 PI 046 CR-PR-ED Global Marketing ST Printed in Germany chlorine free - ecological subject to modification!Display
Thank you for reading this data sheet.For pricing or for further information, please contact us at our UK Office, using the detailsbelow.UK OfficeKeison Products,P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England.Tel: 44 (0)330 088 0560Fax: 44 (0)1245 808399Email: [email protected] note - Product designs and specifications are subject to change without notice. The user is responsible for determining thesuitability of this product.
Dräger Pac 7000 O 2 2) 0 to 25 Vol.-% 19.5 Vol.-% 23.5 Vol.-% 83 18 972 Dräger Pac 7000 O 2 0 to 25 Vol.-% by customer request 83 18 678 Dräger Pac 7000 CO 2 0 to 5 Vol.-% 0.5 Vol.-% 3 Vol.-% 83 18 975 Dräger Pac 7000 CI 2 0 to 20 ppm 0.5 ppm 1 ppm 83 18 978 Dräger Pac 7000 HCN 0 to 50 ppm 10