Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesRosemount 3051S Series of InstrumentationScalable Pressure, Flow, and Level Solutions 3051S Series delivers highest fieldperformance and reliability SuperModule Platform provides a foundationfor integrated pressure, flow, and levelsolutions WirelessHART Protocol enables costeffective installations MultiVariable technology enables fullycompensated mass and energy flow Advanced Diagnostics provides coveragefrom the process to the host system Innovative DP Flowmeters integrate a primaryelement and transmitter into a single device Tuned-System Assemblies and Liquid LevelTransmitters provide cost efficient, optimizedlevel measurementContentsSelection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2Ordering InformationRosemount 3051S Scalable Coplanar Pressure Transmitter . . . . . . . . . . . . . page 4Rosemount 3051S Scalable In-Line Pressure Transmitter . . . . . . . . . . . . . . page 11Rosemount 3051S Scalable MultiVariable Transmitter . . . . . . . . . . . . . . . . . page 16Rosemount 3051SF DP Flowmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22Rosemount 3051S Liquid Level Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . page 43Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 50Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 68Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 78www.rosemount.com

Product Data SheetRosemount 3051S Series00813-0100-4801, Rev MBAugust 2010Achieve More with Rosemount 3051S Series of InstrumentationThe Foundation for Pressure, Flow, and LevelMeasurement SuperModule Platform delivers the highest fieldreliability with all-welded hermetic SST design Ultra and Ultra for Flow provide industry leadingperformance, 10-year stability and a 12-year limitedwarranty Simplify compliance with IEC 61508 safetycertificationThe World’s Only Scalable Platform Optimize performance, functionality and process connections for yourapplication MultiVariable, Advanced Diagnostics and enhanced FOUNDATION fieldbuscapabilities enable better plant performance Seamless integration of flanges, manifolds, remote mount seals and flowelementsIndustry Leading Capabilities Extended To WirelessHART Cost effectively implement wireless on the proven SuperModule platform Realize a decade of virtually maintenance-free performance Optimize safety with the industry’s only intrinsically safe Power Module Implement wireless using existing tools and practices Installation-ready integrated wireless pressure, flow and level solutionsAdvanced Diagnostics Provides Coverage from the Process to the Host Proactively monitor for loop wiring and power supply issues Predict and prevent abnormal process conditions Log process characteristics and device health Extend diagnostic coverage to Safety Instrumented Systems2

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesAdvanced MultiVariable Technology Dynamically calculate mass or volumetric, energy, and totalized flow throughreal time compensation of over 25 variables Customize the level of compensation with the scalable platform Easily configure flow and device parameters with Engineering Assistant software. Achieve up to 0.65% flow accuracy over a 14:1 flow turndownInnovative, Integrated DP Flowmeters Fully assembled and leak tested for out-of-the-box installation Lower installed costs by replacing 10 devices with one integrated flowmeter Reduce straight pipe requirements, lower permanent pressure loss andachieve accurate measurement in small line sizes Measure up to 14:1 flow turndown with % of reading performanceProven, Reliable, and Innovative DP Level Technologies Connect to virtually any process with a comprehensive offering of processconnections, fill fluids, direct mount or capillary connections, and materials Quantify and optimize total system performance with QZ option Operate at higher temperature and in vacuum applications Optimize level measurement with cost efficient Tuned-System AssembliesInstrument Manifolds – Quality, Convenient, and Easy Designed and engineered for optimal performance with Rosemounttransmitters Save installation time and money with factory assembled manifolds Offers a variety of styles, materials, and configurations Enable “flange-less” valve integration with Coplanar design3

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesRosemount 3051S Scalable Coplanar Pressure TransmitterRosemount 3051S Scalable Coplanar Pressure transmitters are the industryleader for Differential, Gage, and Absolute pressure measurement. Thecoplanar platform allows seamless integration with manifolds, primaryelements and seal solutions. Capabilities include: Ultra, Ultra for Flow, and Classic Performance HART/4-20 mA, WirelessHART, FOUNDATION fieldbus protocols Safety Certification (Option Code QT) Advanced Diagnostics (Option Code DA2) Remote Display and Interface (Option Code M7, M8, or M9))3051S Scalable CoplanarPressure TransmitterAdditional InformationSpecifications: page 50Certifications: page 68Dimensional Drawings: page 78Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.ModelTransmitter Type3051SScalable Pressure TransmitterPerformance ClassStandard1Ultra: 0.025 percent span accuracy, 200:1 rangedown, 10-yr stability, 12-yr limited warranty3(1)Ultra for Flow: 0.04 percent reading accuracy, 200:1 turndown, 10-yr stability, 12-yr ltd warranty2Classic: 0.055 percent span accuracy, 100:1 rangedown, 5-yr stabilityConnection TypeStandardCCoplanarMeasurement Pressure RangeDifferentialGageAbsoluteStandard1A-25 to 25 inH2O (-62,2 to 62,2 mbar) -25 to 25 inH2O (-62,2 to 62,2 mbar) 0 to 30 psia (0 to 2,06 bar)2A-250 to 250 inH2O (-623 to-250 to 250 inH2O (-623 to 623 mbar) 0 to 150 psia (0 to 10,34 bar)623 mbar)3A-1000 to 1000 inH2O (-2,5 to 2,5 bar) -393 to 1000 inH2O (-0,98 to 2,5 bar) 0 to 800 psia (0 to 55,2 bar)4A-300 to 300 psi (-20,7 to 20,7 bar)-14.2 to 300 psig (-0,98 to 21 bar)0 to 4000 psia (0 to 275,8 bar)5A-2000 to 2000 psi (-137,9 to 137,9-14.2 to 2000 psig (-0,98 to 137,9N/Abar)bar)Expanded0A(3)-3 to 3 inH2O (-7,47 to 7,47 mbar)N/A0 to 5 psia (0 to 0,34 bar)Isolating DiaphragmStandard2(4)316L SST3(4)Alloy C-276Expanded4Alloy 4005(5)Tantalum6Gold-Plated Alloy 400 (includes Graphite-Filled PTFE o-ring)7Gold-plated 316L SST4Standard Standard Standard Standard Standard

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesTable 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Process ConnectionSizeMaterials of (6)Drain VentNoneAssemble to Rosemount 305 Integral ManifoldAssemble to Rosemount 304 or AMF Manifold and SST traditional flangeAssemble to one Rosemount 1199 SealSSTAssemble to two Rosemount 1199 SealsSSTAssemble to Rosemount 405 Primary ElementAssemble to Rosemount 1195 integral orifice and Rosemount 305 Integral ManifoldAssemble to Rosemount Annubar Primary Element withSST316 SSTCoplanar flangeAssemble to Rosemount Annubar Primary Element withCast C-276Alloy C-276Coplanar flangeAssemble to Rosemount Annubar Primary Element withSSTAlloy C-276Coplanar flange1Coplanar flange/4–18 NPTCS316 SST1Coplanar flange/4–18 NPTSST316 SST1Coplanar flange/4–18 NPTCast C-276Alloy C-2761Coplanar flange/4–18 NPTCast Alloy 400 Alloy 400/K-5001Coplanar flange/4–18 NPTSSTAlloy C-2761Coplanar flange/4–18 NPTCSAlloy C-276Coplanar flangeRC 1/4CS316 SSTCoplanar flangeRC 1/4SST316 SSTCoplanar flangeRC 1/4Cast C-276Alloy C-276Coplanar flangeRC 1/4Cast Alloy 400 Alloy 400/K-500Coplanar flangeRC 1/4SSTAlloy C-276Coplanar flangeRC 1/4CSAlloy C-2761/4–18 NPTTraditional flangeSST316 SST1/4–18 NPTTraditional flangeCast C-276Alloy C-2761/4–18 NPTTraditional flangeCast Alloy 400 Alloy 400/K-5001Traditional flange/4–18 NPTSSTAlloy C-276Traditional flangeRC 1/4SST316 SSTTraditional flangeRC 1/4Cast C-276Alloy C-276Traditional flangeRC 1/4Cast Alloy 400 Alloy 400/K-500Traditional flangeRC 1/4SSTAlloy C-2761DIN-compliant traditional flange/4–18 NPTSST316 SSTVertical mount level flange2-in. ANSI class 150 SST316 SSTVertical mount level flange2-in. ANSI class 300 SST316 SSTVertical mount level flange3-in. ANSI class 150 SST316 SSTVertical mount level flange3-in. ANSI class 300 SST316 SSTVertical mount level flangeDIN- DN 50 PN 40SST316 SSTVertical mount level flangeDIN- DN 80 PN 40SST316 12G21G22G31G41Expanded1/4–18 NPTF32Bottom vent traditional flangeSSTF42Bottom vent traditional flangeRC 1/4SST1F62DIN-compliant traditional flange/4–18 NPTSST1F72DIN-compliant traditional flange/4–18 NPTSSTTransmitter OutputStandardA4–20 mA with digital signal based on HART protocolF(9)FOUNDATION fieldbus protocol(10)XWireless (Requires wireless options and wireless PlantWeb housing)316 SST316 SST316 SST316 SSTBoltingStandard 7/16-in. bolting M10 boltingM12 boltingStandard 5

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesTable 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Housing ded1C1L2C2GMaterialConduitEntry SizeNone (SuperModule spare part, order output code A)PlantWeb housingPlantWeb housingPlantWeb housingPlantWeb housingWireless PlantWeb housingWireless PlantWeb housingJunction Box housingJunction Box housingJunction Box housingJunction Box Housing with output for remote display and interfaceJunction Box Housing with output for remote display and interfaceJunction Box Housing with output for remote display and interfaceQuick Connect (A size Mini, 4-pin male numAluminumSSTAluminumAluminumSSTSST1PlantWeb housingPlantWeb housingJunction Box housingJunction Box Housing with output for remote display and /2/2–14 NPTM20 x 1.51/2–14 NPTM20 x 1.51/2–14 NPT1/2–14 NPT1/2–14 NPTM20 x 1.51/2–14 NPT1/2–14 NPTM20 x 1.51/2–14 NPTStandard Wireless Options (Requires option code X and wireless PlantWeb housing)Update RateStandardWAUser Configurable Update RateOperating Frequency and ProtocolStandard32.4 GHz DSSS, WirelessHARTOmnidirectional Wireless AntennaStandardWKLong Range, Integral AntennaWMExtended Range, Integral AntennaSmartPower StandardPower Module Adapter, Intrinsically Safe (Power Module separate)1(12)Standard Standard Standard Standard Other Options (Include with selected model number)PlantWeb Control FunctionalityStandardFOUNDATION fieldbus Advanced Control Function Block SuiteA01(13)PlantWeb Diagnostic FunctionalityStandardFOUNDATION fieldbus Diagnostics SuiteD01(13)HART Diagnostics SuiteDA1(13)(14)DA2(13)(14)(15) Advanced HART Diagnostics SuitePlantWeb Enhanced Measurement FunctionalityStandardFOUNDATION fieldbus Fully Compensated Mass Flow BlockH01(13)(16)6Standard Standard Standard

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesTable 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Mounting Bracket(17)StandardB4Coplanar flange bracket, all SST, 2-in. pipe and panelB1Traditional flange bracket, CS, 2-in. pipeB2Traditional flange bracket, CS, panelB3Traditional flange flat bracket, CS, 2-in. pipeB7Traditional flange bracket, B1 with SST boltsB8Traditional flange bracket, B2 with SST boltsB9Traditional flange bracket, B3 with SST boltsBATraditional flange bracket, B1, all SSTBCTraditional flange bracket, B3, all SSTSoftware ConfigurationStandardCustom software configuration (Requires Configuration Data Sheet)C1(18)C2Custom flow configuration (Requires H01 and Configuration Data Sheet)Gage Pressure CalibrationStandardC3Gage pressure calibration on Rosemount 3051S CA4 onlyAlarm LimitStandardNAMUR alarm and saturation levels, high alarmC4(13)(18)NAMUR alarm and saturation levels, low alarmC5(13)(18)Custom alarm and saturation signal levels, high alarm (Requires C1 and Configuration Data Sheet)C6(13)(18)Custom alarm and saturation signal levels, low alarm (Requires C1 and Configuration Data Sheet)C7(13)(18)Low alarm (standard Rosemount alarm and saturation levels)C8(13)(18)Hardware AdjustmentsStandardHardware adjustments (zero, span, alarm, security)D1(13)(18)(19)Flange AdapterStandard1/2-14 NPT flange adapterD2(17)ExpandedRC1/2 SST flange adapterD9(17)Custody TransferStandardMeasurement Canada Accuracy ApprovalD3(20)Ground ScrewStandardD4External ground screw assemblyDrain/Vent ValveStandardDelete transmitter drain/vent valves (install plugs)D5(17)ExpandedCoplanar flange without drain/vent portsD7(17)Conduit PlugStandard316 SST Conduit PlugDO(21)Product Certifications(22)StandardE1ATEX FlameproofI1ATEX Intrinsic SafetyIAATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)N1ATEX Type nK1ATEX Flameproof, Intrinsic Safety, Type n, DustNDATEX DustE4TIIS FlameproofTIIS Intrinsic SafetyI4(23)Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard 7

Product Data SheetRosemount 3051S Series00813-0100-4801, Rev MBAugust 2010Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.E5FM Explosion-proof, Dust Ignition-proofI5FM Intrinsically Safe, Division 2IEFM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)K5FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2CSA Explosion-proof, Dust Ignition-proof, Division 2E6(24)I6CSA Intrinsically SafeIFCSA FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)(24)CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2K6E7IECEx Flameproof, Dust Ignition-proofI7IECEx Intrinsic SafetyIGIECEx FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)N7IECEx Type nK7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type nE2INMETRO FlameproofI2INMETRO Intrinsic SafetyK2INMETRO Flameproof, Intrinsic SafetyE3China FlameproofI3China Intrinsic SafetyN3China Type nATEX and CSA Flameproof, Intrinsically Safe, Division 2KA(24)FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2KB(24)FM and ATEX Explosion-proof, Intrinsically Safe, Division 2KCFM, CSA, and ATEX Explosion-proof, Intrinsically SafeKD(24)Sensor Fill FluidStandardInert sensor fill fluidL1(25)O-ringStandardL2Graphite-filled PTFE o-ringBolting MaterialStandardAustenitic 316 SST boltsL4(17)ASTM A 193, Grade B7M boltsL5(4)(17)Alloy K-500 boltsL6(17)ASTM A453, Class D, Grade 660 boltsL7(4)(17)ASTM A193, Class 2, Grade B8M boltsL8(17)Display Type(26)StandardM5PlantWeb LCD DisplayM7(13)(27)(28) Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracketM8(13)(27)Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracketM9(13)(27)Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracketPressure Testing Standard Standard Standard Standard ExpandedP1(29)Hydrostatic testing with certificateSpecial CleaningExpandedP2(17)Cleaning for special servicesP3(17)Cleaning for less than 1PPM chlorine/fluorineMaximum Static Line PressureStandardP94500 psig (310 bar) static pressure limit (Rosemount 3051S CD only)P0(30)6092 psig (420 bar) static pressure limit (Rosemount 3051S2CD only)Calibration CertificationStandardQ4Calibration certificateQPCalibration certificate and tamper evident seal8Standard Standard

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesTable 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Material Traceability CertificationStandardQ8Material traceability certification per EN 10204 3.1Quality Certification for SafetyStandardPrior-use certificate of FMEDA DataQS(13)(18)Safety-certified to IEC 61508 with certificate of FMEDA dataQT(31)Transient ProtectionStandardTransient terminal blockT1(32)(33)Drinking Water ApprovalStandardNSF Drinking Water ApprovalDW(34)Surface Finish CertificationStandardQ16Surface finish certification for sanitary remote sealsToolkit Total System Performance ReportsStandardQZRemote Seal System Performance Calculation ReportConduit Electrical ConnectorStandardGE(35)M12, 4-pin, Male Connector (eurofast )GM(35)A size Mini, 4-pin, Male Connector (minifast )Typical Model Number: 3051S1CD 2A 2 E12 A 1A DA2 B4 M5Standard Standard Standard Standard Standard Standard Standard (1) This option is only available with range codes 2A and 3A, 316L SST or Alloy C-276 isolating diaphragm and silicone fill fluid.(2) Performance Class code 3 is available with Measurement Type code D only.(3) 3051S CD0 is only available with traditional flange, 316L SST diaphragm material, and Bolting option L4.(4) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refiningenvironments.(5) Tantalum diaphragm material is only available for ranges 2A - 5A, differential and gage.(6) “Assemble to” items are specified separately and require a completed model number. Process connection option codes B12, C11, D11, EA2, EA3, andEA5 are only available on differential Measurement Type, code D.(7) Consult an Emerson Process Management representative for performance specifications.(8) Not available with performance class code 3.(9) Requires PlantWeb housing.(10) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety(option code I1), and IECEx Intrinsic Safety (option code I7).(11) Available with output code A only. Available approvals are FM Intrinsically Safe, Division 2 (option code I5), ATEX Intrinsic Safety (option code I1), or IECExIntrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.(12) Long-Life Power Module must be shipped separately, order Part #00753-9220-0001.(13) Not available with output code X.(14) Requires PlantWeb housing and output code A. Includes Hardware Adjustments as standard.(15) Consult an Emerson Process Management representative for availability.(16) Requires Rosemount Engineering Assistant to configure.(17) Not available with process connection option code A11.(18) Not available with output code F.(19) Not available with housing style codes 00, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.(20) Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an EmersonProcess Management representative for additional information.(21) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.9

Product Data SheetRosemount 3051S Series00813-0100-4801, Rev MBAugust 2010(22) Valid when SuperModule Platform and housing have equivalent approvals.(23) Only available with output code X.(24) Not available with M20 or G ½ conduit entry size.(25) Only available on differential and gage measurement types. Silicone fill fluid is standard.(26) Not available with Housing code 7J.(27) Not available with output code F, option code DA1, option code DA2, or option code QT.(28) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Managementrepresentative for additional information.(29) P1 is not available with 3051S CA0.(30) Requires 316L SST, Alloy C-276, or Gold-plated 316L SST diaphragm material, assemble to Rosemount 305 integral manifold or DIN-compliant traditionalflange process connection, and bolting option L8. Limited to Pressure Range (Differential), ranges 2A – 5A.(31) Not available with output code F or X. Not available with housing code 7J. Not available with option code DA1.(32) Not available with Housing code 00, 5A, 5J, or 7J.(33) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, and IG.(34) Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.(35) Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) orFM FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).10

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesRosemount 3051S Scalable In-Line Pressure TransmitterRosemount 3051S Scalable In-line Pressure transmitters are the industryleader for Gage and Absolute pressure measurement. The in-line, compactdesign allows the transmitter to be connected directly to a process for quick,easy and cost effective installation. Capabilities include: Ultra and Classic Performance HART/4-20 mA, WirelessHART, FOUNDATION fieldbus protocols Safety Certification (Option Code QT)3051S Scalable In-LinePressure Transmitter Advanced Diagnostics (Option Code DA2) Remote Display and Interface (Option Code M7, M8, or M9)Additional InformationSpecifications: page 50Certifications: page 68Dimensional Drawings: page 80Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.ModelTransmitter Type3051SScalable Pressure TransmitterPerformance ClassStandard1Ultra: 0.025 percent span accuracy, 200:1 rangedown, 10-yr stability, 12-yr limited warranty2Classic: 0.055 percent span accuracy, 100:1 rangedown, 5-yr stabilityConnection TypeStandardTIn-LineMeasurement TypeStandardGGageAAbsolutePressure RangeGageAbsoluteStandard1A-14.7 to 30 psi (-1,0 to 2,1 bar)0 to 30 psia (2,1 bar)2A-14.7 to 150 psi (-1,0 to 10,3 bar)0 to 150 psia (10,3 bar)3A-14.7 to 800 psi (-1,0 to 55 bar)0 to 800 psia (55 bar)4A-14.7 to 4000 psi (-1,0 to 276 bar)0 to 4000 psia (276 bar)5A-14.7 to 10000 psi (-1,0 to 689 bar)0 to 10000 psia (689 bar)Isolating DiaphragmStandard2(1)316L SST3(1)Alloy C-276Process Assemble to Rosemount 306 Integral ManifoldAssemble to one Rosemount 1199 Seal1/2–14 NPT femaleG1/2 A DIN 16288 male (Range 1-4 only)Standard Standard Standard Standard Standard Standard Non-threaded instrument flange (I-flange) (Range 1-4 only)11

Product Data SheetRosemount 3051S Series00813-0100-4801, Rev MBAugust 2010Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Transmitter OutputStandardA4–20 mA with digital signal based on HART protocolF(4)FOUNDATION fieldbus protocol(5)XWireless (Requires wireless options and wireless PlantWeb housing)Housing StyleMaterialConduit Entry SizeStandard00None (SuperModule spare part, order output code A)11APlantWeb housingAluminum/2–14 NPT1BPlantWeb housingAluminumM20 x 1.51/2–14 NPT1JPlantWeb housingSST1KPlantWeb housingSSTM20 x 1.515AWireless PlantWeb housingAluminum/2–14 NPT15JWireless PlantWeb housingSST/2–14 NPT12AJunction Box housingAluminum/2–14 NPT2BJunction Box housingAluminumM20 x 1.51/2–14 NPT2JJunction Box housingSST12EJunction Box Housing with output for remote display and interfaceAluminum/2–14 NPT2FJunction Box Housing with output for remote display and interfaceAluminumM20 x 1.51/2–14 NPT2MJunction Box Housing with output for remote display and interfaceSST(6)SST7JQuick Connect (A size Mini, 4-pin male termination)Expanded1CPlantWeb housingAluminumG1/21LPlantWeb housingSSTG1/22CJunction Box housingAluminumG1/22GJunction Box Housing with output for remote display and interfaceAluminumG1/2Standard Standard Wireless Options (Requires option code X and wireless PlantWeb housing)Update RateStandardWAUser Configurable Update RateOperating Frequency and ProtocolStandard32.4 GHz DSSS, WirelessHART Omnidirectional Wireless AntennaStandardWKLong Range, Integral AntennaWMExtended Range, Integral AntennaSmartPower Standard1(7)Power Module Adapter, Intrinsically Safe (Power Module separate)Standard Standard Standard Standard Other Options (Include with selected model number)PlantWeb Control FunctionalityStandardA01(8)FOUNDATION fieldbus Advanced Control Function Block SuitePlantWeb Diagnostic FunctionalityStandardD01(8)FOUNDATION fieldbus Diagnostics SuiteDA1(8)(9)HART Diagnostics SuiteDA2(8)(9)(10)Advanced HART Diagnostics SuiteMounting Bracket(11)StandardB4Bracket, all SST, 2-in. pipe and panelSoftware ConfigurationStandardC1(12)Custom software configuration (Requires Configuration Data Sheet)12Standard Standard Standard Standard

Product Data Sheet00813-0100-4801, Rev MBAugust 2010Rosemount 3051S SeriesTable 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Alarm LimitStandardC4(8)(12)NAMUR alarm and saturation levels, high alarmC5(8)(12)NAMUR alarm and saturation levels, low alarmC6(8)(12)Custom alarm and saturation signal levels, high alarm (Requires C1 and Configuration Data Sheet)C7(8)(12)Custom alarm and saturation signal levels, low alarm (Requires C1 and Configuration Data Sheet)C8(8)(12)Low alarm (standard Rosemount alarm and saturation levels)Hardware AdjustmentsStandardD1(8)(12)(13)Hardware adjustments (zero, span, alarm, security)Custody TransferStandardD3(14)Measurement Canada Accuracy ApprovalGround ScrewStandardD4External ground screw assemblyConduit PlugStandardDO(15)316 SST Conduit PlugProduct Certifications(16)StandardE1ATEX FlameproofI1ATEX Intrinsic SafetyIAATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)N1ATEX Type nK1ATEX Flameproof, Intrinsic Safety, Type n, DustNDATEX DustE4TIIS FlameproofI4(17)TIIS Intrinsic SafetyE5FM Explosion-proof, Dust Ignition-proofI5FM Intrinsically Safe, Division 2IEFM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)K5FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2E6(18)CSA Explosion-proof, Dust Ignition-proof, Division 2I6CSA Intrinsically SafeIFCSA FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)(18)K6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2E7IECEx Flameproof, Dust Ignition-proofI7IECEx Intrinsic SafetyIGIECEx FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)N7IECEx Type nK7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type nE2INMETRO FlameproofI2INMETRO Intrinsic SafetyK2INMETRO Flameproof, Intrinsic SafetyE3China FlameproofI3China Intrinsic SafetyN3China Type nKA(18)ATEX and CSA Flameproof, Intrinsically Safe, Division 2KB(18)FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2KCFM and ATEX Explosion-proof, Intrinsically Safe, Division 2KD(18)FM, CSA, and ATEX Explosion-proof, Intrinsically SafeSensor Fill FluidStandardL1(19)Inert sensor fill fluidStandard Standard Standard Standard Standard Standard Standard 13

Product Data SheetRosemount 3051S Series00813-0100-4801, Rev MBAugust 2010Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery.The Expanded offering is subject to additional delivery lead time.Display Type(20)StandardM5PlantWeb LCD DisplayM7(8)(21)(22)Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracketM8(8)(21)Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracketM9(8)(21)Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracketPressure TestingStandard ExpandedP1Hydrostatic testing with certificateS

Product Data Sheet 00813-0100-4801, Rev MB August 2010 Rosemount 3051S Series www.rosemount.com 3051S Series delivers highest field performance and reliability SuperModule Platform provi