Transcription

TEMPERATURE SENSOR KITFOR USE WITH INTELLICENTER , EASYTOUCH ,INTELLITOUCH , SUNTOUCH AND COMPOOL TO EASYTOUCH UPGRADE CONTROL SYSTEMSINSTALLATIONGUIDEIMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONSSAVE THESE INSTRUCTIONS

2Technical Support(800) 831-71338.00 am to 8.00 pm ET8.00 am to 5.00 pm PTKit contentsThe following items are included in the water/air temperature sensorreplacement kit:Temperature Sensor Assembly - P/N 520872 Temperature Sensor, 10k Temperature Sensor - P/N 520326 Temperature Sensor, 10k Ohms, 40 ft - P/N 521583 Temperature Sensor, 10k Ohms, 20 ft - P/N 521584 Hose Clamp (1-7/8” - 5” Clamp) - P/N 476168 Installation Instructions (this manual)Related manualsIntelliCenter Control System User’s Guide (P/N 522990)IntelliTouch Control System User’s Guide (P/N 521075)EasyTouch Control System User’s Guide (P/N 521044)SunTouch Control System User’s Guide (P/N 520785)Water/Air Temperature SensorThe sensor can be used as a water or air sensor. The 10k Ohms TemperatureSensor can be is used with IntelliCenter, IntelliTouch, EasyTouch, SunTouch andCompool to EasyTouch Upgrade Control Systems.P/N 520326 Rev.E 5/2019Temperature Sensor Installation Instructions

3Sensor InstallationNote: See page 4 and 5 for circuit board sensor connector locations.IMPORTANT NOTE: Replacing the existing Water Temperature Sensor.When replacing the existing water temperature sensor, be sure touse drill a 3/8th inch hole into the 3-in or 2-in pipe for the new sensor.Note: The existing water sensor hole is 5/16th inch, and will not fit thenew replacement sensor.1.2.3.4.The existing water sensor is located between the filter pump and thefilter. Remove the sensor.Drill a 3/8th inch hole in the 3-in or 2-in pipe. Position the hose clampover the replacement sensor and gently tighten around pipe.Caution: Do not overtighten clamp.Route the cable up through the low voltage compartment of the LoadCenter or Power Center to the Outdoor Control Panel circuit board.Strip wires back 1/4 inch. Connect the sensor wires to WATER screwterminals. See page 4 and 5 for screw terminal location.Ambient Air Temperature (Freeze Protection)Sensor Replacement Mount sensor in open air, in shaded area, away from air conditioners.Route the cable up through the low voltage compartment of the LoadCenter or Power Center to the Outdoor Control Panel circuit board. Usecable ties to fasten sensor cable to pipes. Strip wires back 1/4 inch.Connect the sensor wires to AIR screw terminals. See page 4 and 5 forscrew terminal location.3/8"DrillPipe2-in or3-in Pipe ClampTemperature Sensor Installation Instructions

4AIRSOLARWATERIntelliCenter ControlSystem Circuit BoardSOLARWATERAIR(J15)IntelliCenter Control System Circuit Board(Air, Water and Solar sensor location)IntelliTouch ControlSystem Circuit BoardEasyTouch ControlSystem Circuit BoardTemperature Sensor Installation Instructions

5VALVE ACTUATORSJ12RESETCR2032 3VSOLARONLYAINTAKE RETURN SOLAR PUMP AUX 1 AUX 2VLV A VLV B VLV CGASHEATERJ9CLNRAUX 3SunTouch ControlSystem Circuit BoardCOMPOOL TO EASYTOUCH WIRING DIAGRAMTRANSFORMERFACTORY WIRINGOUTPUT: 10VAC 18VAC 24VACLOW VOLTAGE CIRCUIT BREAKERSBLU/ WHBLUORG/ WHORGRED/ WHRED10V18V24VTRANSFORMERCONNECTIONS10VAC 18VAC 24VACIMPORTANT NOTE:CAUTION:DO NOT BYPASS INTERNAL HEATERTHERMOSTAT, HIGH LIMIT SWITCH,OR OTHER SAFETY DEVICES.J 13AUX5J 12AUX4J 11AUX3J 10AUX2J9AUX1J8PUMPJ7SPAGAS VALVECONTROLJ 14AUX6HEATERJ 19J6J 21[See Important Note]AI RBLKWATER SOLARSENSORSREDAIR SENSORJ 15J 25BLKREDBLKAUX7J 17THERMOSTATSOLAR SENSORJ 16J 18ONOFFLIMITWATER SENSOR2- SPD SOLAR EHTRPOOL HEATERPRESSURERED10K OHM THERMISTOR SENSORS(Red/Blk wires are interchangeable)J221R ORG BLKYELBLKREDGRN2YI S4 REMOTE3G4BJ2RETURNVALVEACTUATORI NTAKEJ3AUX VALVE Aor SOLARACTUATORRETURNJ4J24COM PORTAUXVALVE BACTUATORVLV AJ5PCB As s y #521099VLV BKBLORGREDYELGRNBLUJ25 Jumper is Factoryset on both pins.For Single Body Systems,the Jumper only needs tobe attached on 1 pin.For Shared EquipmentSystems, the Jumperneeds to be attachedon both pins.AUXILIARY RELAYS (1-7)TO GAS HEATER TERMINALS FORREMOTE CONTROL OPERATION, ORTO FIREMAN'S SWITCH CONNECTION.INTAKEVALVEACTUATORJ23J20COM PORTBLUBLKREDGRNYELBLKGRNYELREDCOM PORT: EasyTouch Indoor Control Panel,RF Transceiver, iS4, iS10 Spa side Remote,IntelliFlo VF IntelliFlo VS, QuickTouch and CP/ET RJ12 Adapter for Indoor Control Panel.and/orEXT CTRL MODTELSPABLUto CONTROL PANELor iS10RJ12 AdapterEasyTouch Indoor Control Panelor iS10 for CP3800 seriesCompool EasyTouch Upgrade ControlSystem Circuit Boardto EasyTouch Indoor Control Panelor iS10 Spa-Side Remote (for CP3800 series)Temperature Sensor Installation Instructions

6Temperature Sensor Installation InstructionsNotes

Notes7Temperature Sensor Installation Instructions

821620 HAWKINS AVE., SANFORD, NC 27330 (919) 566-800010951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 (805) 553-5000WWW.PENTAIR.COMAll Pentair trademarks and logos are owned by Pentair. Intellicenter , EasyTouch , IntelliTouch , SunTouch ,Compool are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or itsaffiliated companies in the United States and/ or other countries. Because we are continuously improvingour products and services, Pentair reserves the right to change specifications without prior notice. Pentairis an equal opportunity employer. 2019 Pentair Water Pool and Spa, Inc.This document is subject to change without notice.*520326*P/N 520326 Rev.E 5/2019Temperature Sensor Installation Instructions

Hose Clamp (1-7/8” - 5” Clamp) - P/N 476168 Installation Instructions (this manual) Water/Air Temperature Sensor The sensor can be used as a water or air sensor. The 10k Ohms Temperature Sensor can be is used with IntelliCenter, IntelliTouch, EasyTouch, SunTouch and Comp