UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDSAPPENDIX – TOILET ROOMSAPPENDIX – Toilet RoomsDocument revision history: 08/2019 – Original PublicationDateSectionDescription of ChangePART 1 – GENERAL1.1 Design Summarya. All Gender Restrooms All new buildings shall contain a minimum of one All Gender Restroom. Preferred if each floor contains a minimum of one All Gender Restroom. Note: City of Eugene recognizes fixtures in all gender restrooms serving 50% male and 50% female. All Gender Restroom Design Criteria.i. All Gender, Single-Occupant Restroom1. The intent is that the restroom can be accessed by a single person of any gender.2. Design Criteria:a. One-room facility equipped with a sink, toilet and optional urinal (partitions not necessary).b. Locking entry door.c. Feminine hygiene receptacle in addition to UO standard bathroom accessories.d. Changing table is desired.ii. All Gender, Single-Occupant ADA Restroom1.The intent is that the restroom can be accessed by a single person of any gender AND the room isaccessible per ADA guidelines.2. Design Criteria:a. Meets ADA wheelchair accessibility guidelines.b. One-room facility equipped with a sink, toilet and optional urinal (partitions not necessary).c. Locking entry door.d. Feminine hygiene receptacle in addition to UO standard bathroom accessories.e. Changing table is desired.iii. All Gender, Multi-User Restroom:1. The intent is that the restroom can be accessed by multiple people of any gender at the same time.2. Design Criteria:a. Multi-stall facility equipped with sinks and toilets (urinals optional).b. Each toilet and urinal must be enclosed within a stall that has a lockable door and provides privacy forall occupants.c. Feminine hygiene receptacles provided in all stalls. This is in addition to other UO standard bathroomaccessories.d. Changing table is desired.iv. All Gender, Multi-User ADA Restroom:1.The intent is that the restroom can be accessed by multiple people of any gender at the same time ANDthe room is accessible per ADA guidelines.2. Design Criteria:a. Meets ADA wheelchair accessibility guidelines.b. Multi-stall facility equipped with sinks and toilets (urinals optional).c. Each toilet and urinal, if provided, must be behind enclosed within a stall with a lockable door andprovide privacy for all occupants.08/2019APPENDIX – Toilet RoomsPage 1 of 8

UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDSAPPENDIX – TOILET ROOMSd. Feminine hygiene receptacles provided in all stalls. This is in addition to other UO standard bathroomaccessories.e. Changing table is desired. Every Building should have a baby changing station in at least one restroom that is accessible to both men andwomen.1.2 Spatial Considerationsa. Not applicable.1.3 Qualificationsa. Not applicable.PART 2 – PRODUCTS2.1 Finishesa. Flooring Glazed ceramic or porcelain tile in large public restrooms.i. Minimum tile format 4 inch x 4 inch.ii. Maximum tile format 12 inch x 12 inch.iii. Prefer mottled finish. Mortar Grout to be used. No epoxy grout. Grout lines and tile must be sealed.b. Walls Glazed ceramic tile in large public restrooms.i. Minimum tile format 4 inch x 4 inch.ii. Maximum tile format 6 inch x 6 inch. Mortar Grout to be used. No epoxy grout. Grout lines and tile must be sealed. Wainscot to 4 ft above floor.c. Storage For toilet rooms without counters place stainless shelf adjacent to sink; large enough to place notebooks etc.i. Royce Rolls HDS12 shelf model is guideline. Counters with trash receptacles placed underneath;i. Must be accomplished without conflicting with wheelchair knee space.ii. Counter grommets shall be 8in diameter over waste receptacle. Provide coat hooks in various locations; including individual stalls and/or wall hooks.i. Bobrick B-7671 model is guide.2.2 Accessoriesa. Grab bars: (CFCI; Contractor Furnished & Contractor Installed.) Stainless steel Peened grip Concealed fasteners 1.5in diameter Installed as required per ADA Bobrick B-6106 model is guide.b. Mirrors: (CFCI) Stainless steel frames or no frames. Provide full length mirror in accessible rooms.08/2019APPENDIX – Toilet RoomsPage 2 of 8

UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDSAPPENDIX – TOILET ROOMS NO mounting on doors. Corners are to be welded and ground smooth. Bobrick B-290 model is guide. Hangers are to be rigid, tamper and theft-resistant installation.c. Toilet Partitions: (CFCI) Solid plastic panels that contain color all the way through the panel allowing for sanding repair of scratches orother damage. NO particle board within panel construction. Partitions must have stainless hardware vs. chrome plated. Preferred model type: Bobrick style 1092 Sierra Brace panels floor to ceiling or floor mounted with overhead braces when possible.d. Some Accessories are to be OFCI. See Part 3 below for products.e. Install solid backing at all locations to receive toilet accessories.f. Do not mount dispensers on mirrorsg. Paper towel dispenser must be installed near sinks, and must be ADA compliant.h. Soap dispenser must be installed in such a way that the top can be easily opened for re-fill of soap.i. Waste receptacle location shall be planned and provided for.j. Toilet paper dispenser in restrooms with grab bars shall be mounted so the bottom of the dispenser is 6in above thegrab bar.k. Sanitary napkin receptacles are to be installed with the top of the device no more than 48in above floor, and withineasy reach of the toilet.l. Seat cover dispensers are to be installed with the dispensing slot no more than 48in above floor. The dispenser mustbe installed in such a way that product can be loaded; at least 6in above grab bars.2.3 Signagea. All Gender Restrooms All Gender, Single-Occupant Restroomi. Size: 8”x8”, Font: Kievit Pro Medium08/2019APPENDIX – Toilet RoomsPage 3 of 8

UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDS All Gender, Single-Occupant ADA Restroomi. Size: 8”x8”, Font: Kievit Pro Medium All Gender, Multi-User Restroomi. Size: 8”x8”, Font: Kievit Pro MediumAPPENDIX – TOILET ROOMSMULTI-USER All Gender, Multi-User ADA Restroomi. Size: 8”x8”, Font: Kievit Pro MediumMULTI-USER08/2019APPENDIX – Toilet RoomsPage 4 of 8

UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDSAPPENDIX2.4 MEP Systemsa. Mechanicalb. Electrical All lighting shall be in the 20-30 foot candle range. Sensor switches are to be evaluated and placed for maximum coverage. Mytech infrared/ultrasonic wall switch and Wattstopper.c. Plumbing Floor drain required. Install at low point of floor. Provide hose bib near lavatories.PART 3 – EXECUTION3.1 Installationa. Owner Furnished Contractor Installed ItemsDispenserManufacturerPart NumberVendorToiletPaperVista Hands FreePush BarRolledPaperTowelDispenserAPPENDIX5

UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDSToilet SeatCoverDispenserSmokedImp1122LTX- 12Foam SoapDispenserGOJOIndustriesGJ1919 with J6N orJ6-RC 187.07SupplyworksAPPENDIXAPPENDIXSupplyworks6

UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDSTrash CansSlim Jim 23 StationThis ispreferredKola StationFoundationVertical, FlushMountItem# 39F736MFG# 100-EVBPGraingerAPPENDIX3.2 Interface with other productsa. Not applicable.3.3 Testinga. Not applicable.APPENDIX7

UNIVERSITY OF OREGON CAMPUS DESIGN STANDARDSAPPENDIX3.4 Traininga. Not applicable.APPENDIX8

Preferred if each floor contains a minimum of one All Gender Restroom. Note: City of Eugene recognizes fixtures in all gender restrooms serving 50% male and 50% female. All Gender Restroom Design Criteria. i. All Gender, Single-Occupant Restroom 1. The intent is that the restroom